RE: Single ended termination
- - <[email protected]> Fri, 12 Feb 2021 18:26:06 +0100 (CET)
| Newsgroups | gmane.comp.hardware.bus.can |
|---|---|
| Message-ID | <[email protected]> |
Hello Andreas, sincere thanks for providing, hosting and managing the list over the years. Regrettably I have to agree, it's becoming silent in the CAN world. My company started the first CAN device (an DSP-402-drive) back in the late= nineties. We had many CAN products since then and even some very special setups (i.e.= CAN over plastic fiber in an magnetic resonance medical device). But focus shifted, nowadays we do most of our new stuff for ethernet varian= ts like Profinet or Ethercat. Yes, we still sell CAN stuff, but no new developed devices. It was always fun following the list, i.e. Johns articles about the Olympic= rings were absolute highlights. The list was very informative, educative and always a good place to ask spe= cial questions. But times are changing, for me it's now still fun reading here but not long= er something I need for work. So from my side it's absolutely ok to turn off the list if it's getting dif= ficult running it in a secure way. Thanks again Matthias > Neubauer, Andreas <[email protected]> hat am 12.02.2021 16:46 g= eschrieben: >=20 > =20 > Hi John, > the list has a long history indeed, and the experienced contributors like= you are what makes it worthwhile in the first place. I always really enjoy= ed managing the list, but I notice that the community has become smaller an= d smaller over the years (585 subscribers currently, 95% of them have been = silent for years). We had less than 20 threads last year, so I wonder if it= still makes sense to keep the list up and running to be honest. The majord= omo software it runs on must be shut down soon because it has long been out= dated (no updates available). It=E2=80=99s possible to migrate to a hosted = list service, but is it worth the effort? It might be more rational to cons= ider closing the list. What do you think? >=20 > Andreas > CANLIST Administration >=20 >=20 > From: [email protected] <canlist-owner@vector-informati= k.com> On Behalf Of John Dammeyer > Sent: Thursday, February 11, 2021 10:06 AM > To: 'CAN Mailinglist' <[email protected]> > Subject: RE: [CANLIST] Single ended termination >=20 > Works like a charm. Thanks for that. >=20 > I was just privately commenting to Heikki about the history of this CAN l= ist and how it spawned from comp.arch.embedded (1997) and from there Ken T= indell formed the original group. When Ken left Univeristy of Upsalla Vec= tor kindly took it over without any advertising or prejudice. So impressiv= e in this day and age. >=20 > So thanks again and to you and Vector for supporting a non-partisan open = forum. >=20 > John Dammeyer >=20 >=20 > From: [email protected]<mailto:canlist-owner@vector-inf= ormatik.com> [mailto:[email protected]] On Behalf Of Neub= auer, Andreas > Sent: February-11-21 12:53 AM > To: CAN Mailinglist ([email protected]<mailto:[email protected]>) > Subject: RE: [CANLIST] Single ended termination >=20 > Hi, > please go to https://canlist.org/ directly if you do not get redirected t= here from http://www.canlist.org/.<http://www.canlist.org/> The SSL certifi= cate doesn=E2=80=99t cover the variant with =E2=80=9Cwww=E2=80=9D and I had= missed to redirect this automatically. This is fixed now, but some browser= s might have cached the previous redirect. >=20 > Andreas > CANLIST Administration >=20 >=20 > From: [email protected]<mailto:canlist-owner@vector-inf= ormatik.com> <[email protected]<mailto:canlist-owner@vect= or-informatik.com>> On Behalf Of John Dammeyer > Sent: Thursday, February 11, 2021 9:23 AM > To: [email protected]<mailto:[email protected]> > Subject: RE: [CANLIST] Single ended termination >=20 > Heikki, > Your message did come through as did a number of others a day after I fir= st posted mine. >=20 > I've also noticed and reported that the www.canlist.org<http://www.canlis= t.org> site is considered dangerous by several browsers. Something about = a security certificate. >=20 > Back around 2011, TI's Steve Corrigan had retired and he and I had starte= d looking into cable behaviour on CAN messages. I'd sent him some surplus = Thick DeviceNet cable for some experiments. However he unfortunately passe= d before we had much of a chance to do anything with that. Never really go= t back to it. He really was the expert on this bus. >=20 > Since then most of my CAN systems have had no more than about 10 nodes an= d there are some rules broken. Mostly on stub lengths. It's a difficult b= attle with mechanical engineers who don't understand that 50 ohm cable is d= ifferent from 120 ohm cable. Especially when the thin 50 ohm fits so well = and bends so easily. >=20 > This summer or fall I hope to get back into some really long CAN bus netw= orks at slower bus rates. Maybe 100kbps for garden lighting and security. = Such as system may not use 120 ohm cable for everything just to do some te= sting. >=20 > John Dammeyer >=20 >=20 >=20 > From: [email protected]<mailto:canlist-owner@vector-inf= ormatik.com> [mailto:[email protected]] On Behalf Of Heik= ki Saha > Sent: February-11-21 12:08 AM > To: [email protected]<mailto:[email protected]> > Subject: [CANLIST] Single ended termination >=20 > Hello, >=20 > Had problems getting this through, John already provided nice scope scree= nshot as an example. >=20 > The purpose of the terminator is to get the end of the transmission line = look like an infinitely long line with impedance equal to the line impedanc= e (120ohm with CAN) and thus prevent reflections. Thus, single terminator m= ay be installed into one end, but the another end remains unterminated (inf= inite impedance), which leads into over- and undershoots. While the communi= cation will pass through, the transmission line is still broken. From pract= ical point of view, the most significant risk is that any other problem mor= e will lead into total black-out. And one shall keep in mind that the physi= cal layer design has a direct effect on the bit error probability, which is= a basis for residual error rate, which has further effect on the availabil= ity and safety performance of the entire system -- it is easy to violate th= e system requirements with a poor CAN cabling design. >=20 > There are some reference designs (published by Daimler) in the literature= for centre termination but they cannot be recommended, because each of suc= h networks needs to be intentionally fine tuned. In addition to the clumsy = design, such will be a service nightmare. >=20 > My recommendation is to adopt a standard cabling and connector scheme, wh= ere you'll find batch cables, Y- or V-branches and termination plugs, e.g. = MiniChange, M12 or Deutsch DT04/06 series. >=20 > Best regards, >=20 > Heikki Saha, CTO > M.Sc. Automation > Dr.Tech. Electronics > TK Engineering Oy > Hovioikeudenpuistikko 13 as 3, 65100 Vaasa > +358 (0)50 588 6894 > email: [email protected]<mailto:[email protected]> > skype: heikki.saha_tke >=20 > We are also in the 17th iCC: https://www.can-cia.org/icc -- Subscribe, unscribe, and archives at www.canlist.org - report any problems to <[email protected]>