Re: Regarding issue with mode2 data generation and IR recording
A <[email protected]> Thu, 27 Jun 2019 14:21:07 +0200
| Newsgroups | gmane.comp.hardware.lirc |
|---|---|
| Message-ID | <trinity-0d41e630-e555-47e0-a239-9f72f7a1de57-1561638067540@msvc-mesg-gmx022> |
Am 27.06.19 um 09:10 schrieb Bengt Martensson > On 6/27/19 6:48 AM, sabeer sam wrote: > > Respected one, > > I tried the way you told to do for recording the values, but am getting > > same results. I covered the sensor and also placed a 100nf capacitor in > > between plus and ground, but still it's throwing random values when I > > run mode2 command before pressing the button > > If you get pulses when the sensor is in absolute darkness your hardware > is broken. Replace. Use high-quality products for example Vishay, avoid > low-cost junk. > > > and when I start recording > > the button values am getting different values each time. > > As I wrote before, this is normal (within limits). > > Without any more details, there is no way to help. Photos perhaps? I had this effect when the carrier frequency demodulation of the IR receiver (TSOP38* offer different carrier frequencies) did not match the IR signal frequency (455 kHz in my case). Which TSOP38* do you have? Does its carrier frequency match the carrier frequency of your IR source? PS: This is not a possible explanation for getting signals in complete darkness. > > Greetz, > > Bengt