Re: [Ee] Field mill
David VanHorn <[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.pic |
|---|---|
| Message-ID | <CAB115wGLJVdLCE3PNQpirv7hc1EZm6e-FpQMrtjk9AL8Gd+Q3A@mail.gmail.com> |
Finally found a good youtube on this: The Weather Channel, Sky on Fire. It doesnt go into much detail on the rocket facility though. On Tue, Jun 10, 2025, 4:21 AM David VanHorn <[email protected]> wrote: > Well, I finally found the odd duck I was looking for. Pasco scientific, > PS-3211 > > It has a 30V bipolar range and communicates by bluetooth by phone app. > > About $40 on ebay. > > > On Sat, Jun 7, 2025, 3:56 PM David VanHorn <[email protected]> wrote: > >> " As a hypothetical, if you lay a 100ft pair of 24AWG wires with 300V >> insulation on the ground, and lightning strikes one end, what potential >> appears on the other end? The potential is with respect to what? And for >> how long does the potential exist? Is it likely and/or possible and/or >> desirable for the wire to survive a direct strike at one end of the cable?" >> >> The potential that matters is what ends up across me or my vehicle, or my >> equipment. It lasts some milliseconds. It's not likely that the field >> mill or the wire would survive a direct hit. 20 to 50 kA does interesting >> things. >> The old trueism that lightning never strikes the same place twice isn't >> really true, but frequently it's somewhat true as "the same place" isn't >> there anymore. :) >> >> I'd urge you to read up on Charles Steinmentz and everything by Martin >> Uman. >> https://en.wikipedia.org/wiki/Martin_A._Uman >> >> That copper wire MAY perf it's insulation near the tripod and leave me >> with only a few hundred volts, or it may become a plasma channel with >> resistance of a few ohms leading the bulk of the strike directly to me. >> I'm not willing to risk a copper path that leads directly to me. Even >> if only a few hundred volts, it could easily be lethal. It will be rather >> humid, and I may well be very wet. >> I will also be FAR from any medical support. Heart goes into Vfib and I'm >> done. >> >> >> On Sat, Jun 7, 2025 at 4:02 AM Jason White < >> [email protected]> wrote: >> >>> I used to design direct lightning strike circuit protection networks for >>> avionics - so I might be biased. >>> >>> You probably already possess about a dozen ways of getting a reading to >>> you >>> safely with stuff you have just laying around. >>> >>> As a hypothetical, if you lay a 100ft pair of 24AWG wires with 300V >>> insulation on the ground, and lightning strikes one end, what potential >>> appears on the other end? The potential is with respect to what? And for >>> how long does the potential exist? Is it likely and/or possible and/or >>> desirable for the wire to survive a direct strike at one end of the >>> cable? >>> >>> Suppose the end of the cable was attached to an indicator: a $5 meter, or >>> LED sting, or whatever. What would it take to render said indicator safe >>> to >>> stand next to and look at? Is it possible for the indicator to be usable >>> without ever touching it? Is it likely and/or possible and/or desirable >>> for >>> the indicator to survive a direct strike at one end of the cable? >>> >>> I can speculate, but I'd like to hear what you and others think. >>> >>> I'm genuinely curious about the answers. My intuition tells me one thing, >>> but maybe I could be wrong. >>> -- >>> http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive >>> View/change your membership options at >>> https://mailman.mit.edu/mailman/listinfo/piclist >>> >> -- http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at https://mailman.mit.edu/mailman/listinfo/piclist