Re: [EE} Protecting CAN bus
David C Brown <[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.pic |
|---|---|
| Message-ID | <CAFo_nNqaL5ZTKrY-Jrv=MCDZXTdqEQOwPWuKexim7vPTNqBAOA@mail.gmail.com> |
Yes I am using the correct termination resistors and have a ground reference in the cable. My boards are designed for through hole components but i night be able to cludge SOT23s in. Am I right that one connects cathode1 and cathode2 to the tmo lines of the bus and common cathode to ground? __________________________________________ David C Brown 43 Bings Road Whaley Bridge High Peak Phone: 01663 733236 Derbyshire eMail: [email protected] SK23 7ND web: www.bings-knowle.co.uk/dcb <http://www.jb.man.ac.uk/~dcb> *Sent from my etch-a-sketch* On Sat, 28 Jun 2025 at 11:37, Sean Breheny <[email protected]> wrote: > There are specialized TVS diodes meant for use with CAN. One I've used > before is the PESD1CAN,215 from Nexperian. They have lower than typical > capacitance to avoid affecting the signal. > > I would put these TVSes on each node. > > Do you have termination resistors at each end of the cable? > > I assume that you have a "ground" reference wire in the cable as well to > make sure that the common mode voltage at each node isn't too large? > > I would say that any time you have wires of significant length entering > your house there should be lightning protection directly to a ground rod > right before the point of entry to the house. This should probably be gas > discharge tubes to be able to handle much greater current than TVSes. You > would think that the risk would be non-existent since the wires are running > close to the ground but that's not true. A lightning strike anywhere near > those wires could cause momentary potential differences of thousands of > volts between those lines and the local ground. > > Sean > > > On Fri, Jun 27, 2025 at 1:35 PM David C Brown <[email protected]> wrote: > > > I am using a CAN bus with MC2562 drivers for a home control system. > > This allows a unit in my hall to monitor and control various things in my > > garage: car door, pedestrian door, lights, alarm. > > The garage is some 50 meters from the house and I use CAT5 cable running > in > > conduit at ground level for the bus. > > > > Naturally I am concerned about lightning and other nasties so I am > fitting > > a bidirectional TVS diode on each side of the bus. > > My question is: do I need those diodes on every device connected to the > > bus or is it sufficient to fit them only on the two units at each end? > > I ask because I have a suspicion that putting more TVS diodes on the line > > is degrading the signal > > > > > > __________________________________________ > > David C Brown > > 43 Bings Road > > Whaley Bridge > > High Peak Phone: 01663 733236 > > Derbyshire eMail: [email protected] > > SK23 7ND web: www.bings-knowle.co.uk/dcb > > <http://www.jb.man.ac.uk/~dcb> > > > > > > > > *Sent from my etch-a-sketch* > > -- > > http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive > > View/change your membership options at > > https://mailman.mit.edu/mailman/listinfo/piclist > > > -- > http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive > View/change your membership options at > https://mailman.mit.edu/mailman/listinfo/piclist > -- http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at https://mailman.mit.edu/mailman/listinfo/piclist