which crystal frequency should be used to calculate CAN baud rate?

"Charles Chao Wang" <chao_wang99-/[email protected]>
Newsgroups gmane.comp.hardware.microcontrollers.tini
Message-ID <[email protected]>
Hi,

I am useing TINIs400 and TINIm400, and I am doing CAN bus. I know the baud
rate is calculated as:

baud rate (bits per second) = 18.432 x 10^6 / BRP / (1
+ TSEG1 + TSEG2)


But in TINIm400, we should use 18.432MHz or 25MHz. I find the cystal is
25MHz on the schematic.

Please help~~~~~~~~, I am on my final project.

Thanks a lot.