RE: Access control with prox cards
"Kelly Smith" <[email protected]> Fri, 4 Jun 2004 07:41:48 -0700
| Newsgroups | gmane.comp.hardware.microcontrollers.tini |
|---|---|
| Message-ID | <[email protected]> |
Dear Peter - Chris Fox might have a solution, so you could try contacting him. Ref: http://lists.dalsemi.com/maillists/tini/2003-September/040612.html Also... A round about way of doing 1-Wire interfacing using a TINI, that might be worth investigating is in the DalSemi\MAXIM Application Note 193- "Extending 1-Wire Range With Network Proxies", and could be applied to some of the off-the-shelf door lock\security systems that use a DS2406 to drive a solenoid "lock". This uses the 'NetAdapter' classes (for remote 1-Wire access); I have used on a TINI running in California, all the way to England, and it is very releiable. "NetAdapter is a network-based DSPortAdapter. It allows for the use of an actual DSPortAdapter which isn't on the local machine, but rather is connected to another device which is reachable via a TCP/IP network connection." Ref: http://www.ibutton.com/TINI/applications/lock/index.html <- "TINI Access Control System" This would be a "roll-your-own" solution, but I know that others on the TINI SIG have done this. To quote from the above noted lock application: "A good choice for the electronic door strikes is Securitorns UnLatch®. It is motorized, sized to a commercial door strike plate and easily installs into the door jam. TINI activates this strike with a short pulse on the UnLatchs "Trigger" input. This smart strike then does the rest. (Note this strike will only work with cylindrical door lock sets.)" Also, using Tynamo (Shawn Silverman's excellent TINI Web Server), would be an expedient way to write a servlet interface to a door strike solenoid. He has examples (Java source code) for interfacing to any number of sensed DS2406's on a MicroLAN (1-Wire Network), using a TINI. Ref: http://tynamo.qindesign.com/ I hope that helps! Best regards, Kelly Smith -----Original Message----- From: tini-admin-6tN4nzCoH/[email protected] [mailto:tini-admin-6tN4nzCoH/[email protected]]On Behalf Of Peter Brown Sent: Friday, June 04, 2004 4:02 AM To: tini-6tN4nzCoH/[email protected] Subject: [TINI]Access control with prox cards HI all, just wondering if anyone has an access control (door lock ) using HID prox readers , with remote card admin via TCP/IP I need to control 4 readers 4 doors with mag locks & 4 egress buttons per building. Admin office is located 2500 Km away ( Yes I'm In Australia ) If one of you very clever people have a system up & running I would be crazy to try to "re-invent the wheel" so to speak. Peter Brown. DTW Theatre Technology. mailto:[email protected] <mailto:[email protected]> mobile: +61 418 522 417 Fax: +61 418 523 522 _______________________________________________ TINI mailing list TINI-6tN4nzCoH/[email protected] To UNSUBSCRIBE, edit your profile, or see list archives: http://lists.dalsemi.com/mailman/listinfo/tini _______________________________________________ TINI mailing list TINI-6tN4nzCoH/[email protected] To UNSUBSCRIBE, edit your profile, or see list archives: http://lists.dalsemi.com/mailman/listinfo/tini