RE: QADC continuous scan mode...

"Bevan Weiss" <[email protected]>
Newsgroups gmane.comp.hardware.motorola.microcontrollers
Message-ID <[email protected]>
 
Any read of the QADC result register will give valid data for the previous
QADC operation.  Only when a QADC operation has fully completed is it
written to the result register and this is done as an atomic operation, ie
it will never overlap with a read.


Regards,
Bevan 


________________________________

From: csuozzo [mailto:[email protected]] 
Sent: Wednesday, March 30, 2005 5:43 PM
To: [email protected]
Subject: [MPC500] QADC continuous scan mode...



I am operating my QADC software triggered continuous scan mode.  The MPC555
user 
manual states that "software can read a result value at any time."  My
question is, wouldn't 
you need to check the status register before you read the value in the
result register to 
make sure that the value you're reading isn't the one currently being
updated?  Sorry for 
the newbie question, I'm new to this stuff.  Thanks!



-----------------------------------------------------------