Re: Re: Re: Fwd: Re: More precise values in Analyzer
Eugene Kuleshov <[email protected]>
| Newsgroups | gmane.comp.java.objectweb.asm |
|---|---|
| Message-ID | <[email protected]> |
Joshua Warner wrote: > I looked at SourceValue and SourceInterpreter, and it appears that > when a SourceValue comes from a parameter (or this pointer or > exception variable), it just reports the source as an empty set. So, an empty set would be an indication that value came from this or from method parameters and variable slot would give you parameter number Note to take value length into account, i.e. long will take two variables, so next params will be shifted to the following variables. regards, Eugene
message-footer.txt
(text/plain, 238 B)
-- You receive this message as a subscriber of the [email protected] mailing list. To unsubscribe: mailto:[email protected] For general help: mailto:[email protected]?subject=help OW2 mailing lists service home page: http://www.ow2.org/wws