Re: Fwd: gemalto dot net smart card ATR

Andreas Wallner <[email protected]>
Newsgroups gmane.comp.lib.muscle
Message-ID <[email protected]>
Hi,

Not really the right list for general protocol questions, but anyway: Datarate switches after the ATR is completed (12 etus after last edge).
What happens then depends on the ATR. The card is either in negotiable mode, then communication stays the same until the reader issues a PPS. Otherwise it is in specific mode, then datarate changes after the ATR. Please read ISO7816-3 6.3.1 regarding this.

Regarding datarate itself, one etu = F/(D f), as written in 7.1 of the same spec.

BR
Andreas

On 5 August 2015 06:53:53 CEST, Hassan Mahmood <[email protected]> wrote:
>Hi:
> i have developed smart card interface for cryptoflex on FPGA, now i am
>working on Dot net Smart cards.
>when I insert my card in the system developed for Cryptoflex I only get
>TS(3B) in response of ATR and after that my READER STUCK some where.
>F=372 and D=12 for cryptoflex  and F=512 and D=32 for Dot net smart
>card
>
>what would be new ETU @ 4Mhz!!
>  Or m i missing something!!
>will data rate change after transmission of first byte of ATR, i.e. TS?
>
>
>------------------------------------------------------------------------
>
>_______________________________________________
>Muscle mailing list
>[email protected]
>http://mail.lists.drizzle.com/mailman/listinfo/muscle_lists.drizzle.com

_______________________________________________