Re: Fwd: gemalto dot net smart card ATR

Mr Nitin Agrawal <[email protected]>
Newsgroups gmane.comp.lib.muscle
Message-ID <[email protected]>
Hi ! Data rate doesn't change after transmission of first byte. It's only after successful completion of PPS.To know exactly what's going wrong, you can spy the session. RegardsNitin Kumar Agrawal 


     On Wednesday, 5 August 2015 10:24 AM, Hassan Mahmood <[email protected]> wrote:
   

 
Hi:   i have developed smart card interface for cryptoflex on FPGA, now i am working on Dot net Smart cards.   when I insert my card in the system developed for Cryptoflex I only get TS(3B) in response of ATR and after that my READER STUCK some where.     F=372 and D=12 for cryptoflex  and F=512 and D=32 for Dot net smart card
what would be new ETU @ 4Mhz!!  Or m i missing something!! will data rate change after transmission of first byte of ATR, i.e. TS?

_______________________________________________
Muscle mailing list
[email protected]
http://mail.lists.drizzle.com/mailman/listinfo/muscle_lists.drizzle.com

_______________________________________________
Muscle mailing list
[email protected]
http://mail.lists.drizzle.com/mailman/listinfo/muscle_lists.drizzle.com
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.