Re: [mh] Insteon problems with new PLM
Walter F Kissel <[email protected]>
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <[email protected]> |
Off topic but is there a simple answer on how to install Win32::Setupsup for the current version of Active Perl or Strawberry Perl? CPAN has compile errors. Thanks. On 10/16/2019 4:31 PM, Spencer Ryan wrote: Yeah, factory reset it again, and assuming your devices are i2cs all you should have to do is "link to interface" On Wed, Oct 16, 2019, 5:30 PM Carl McGrath <[email protected]<mailto:[email protected]>> wrote: I have experienced what sounds similar with KeyPadLink units, found I had to factory reset to get them to behave and respond properly. On 10/16/19 4:03 PM, Seann via misterhouse-users wrote: > All, > I recently replaced my old, and issue prone PLM (2412S V3.1) with a > new model, a 2413s. While running into issues that I have seen on the > mailing list and forums before, mainly with having to manually re-link > devices with the PLM, I came across an error that I can't find any > data on. > Two of my lamplinc devices refused to sync or link (manual linking > doesn't seem to take either, have tried it two times each way, via > link as controller in MH, and by manually on the PLM via the set > button), and return the error "pre_nak_long_db_search" as part of the > NACK sent back. I can't find anything at all on google for this > specific message, so I am stumped and wondering if anyone else has > seen this? > The other issue I have run into is I have a Keypadlinc that is > refusing to sync/link, but unlike the lamplinc's it doesn't return an > actual NAK message, it just blankly NACK's anything from the new PLM, > even after a factory reset. > > I am running the latest master branch code, and aside from dropped > messages and table errors on the old PLM, things were working very > well on my issue devices mentioned above. > > > The logs for this, on debug are: > 10/16/19 14:38:50 [Scan all link tables] Now scanning: > $Ceiling_fan_light (3 of 15) > 10/16/19 14:38:50 [Insteon::AllLinkDatabase] WARN The link table for > $Ceiling_fan_light has changed. > 10/16/19 14:38:50 [Insteon::ALDB_i2] $Ceiling_fan_light reading ALDB > at location: 0x0000 > 10/16/19 14:38:50 [Insteon::BaseObject] WARN!! encountered a nack > message () for $Ceiling_fan_light. It may be unplugged, have a burned > out bulb, or this may be a new I2CS type device that must first be > manually linked to the PLM using the set button. > 10/16/19 14:38:50 [Insteon::BaseObject] WARN: Now calling message > failure callback: &Insteon::_get_next_linkscan_failure(1) > 10/16/19 14:38:50 [Scan all link tables] WARN: failure occurred when > scanning $Ceiling_fan_light. Moving on... > 10/16/19 14:38:50 [Scan all link tables] Now scanning: > $Left_Nightstand (4 of 15) > 10/16/19 14:38:50 [Insteon::AllLinkDatabase] WARN The link table for > $Left_Nightstand has changed. > 10/16/19 14:38:50 [Insteon::ALDB_i2] $Left_Nightstand reading ALDB at > location: 0x0000 > 10/16/19 14:38:51 [Insteon::BaseInterface] DEBUG: PLM > command:insteon_ext_received; Device command:read_write_aldb; > type:direct; group: > 10/16/19 14:38:52 [Insteon::BaseObject] WARN!! encountered a nack > message (pre_nak_long_db_search) for $Left_Nightstand. It may be > unplugged, have a burned out bulb, or this may be a new I2CS type > device that must first be manually linked to the PLM using the set > button. > 10/16/19 14:38:52 [Insteon::BaseObject] WARN: Now calling message > failure callback: &Insteon::_get_next_linkscan_failure(1) > 10/16/19 14:38:52 [Scan all link tables] WARN: failure occurred when > scanning $Left_Nightstand. Moving on... > 10/16/19 14:38:52 [Scan all link tables] Now scanning: > $Right_Nightstand (5 of 15) > 10/16/19 14:38:52 [Insteon::AllLinkDatabase] WARN The link table for > $Right_Nightstand has changed. > 10/16/19 14:38:52 [Insteon::ALDB_i2] $Right_Nightstand reading ALDB > at location: 0x0000 > 10/16/19 14:38:52 [Insteon::BaseInterface] DEBUG: PLM > command:insteon_ext_received; Device command:read_write_aldb; > type:direct; group: > 10/16/19 14:38:53 [Insteon::BaseObject] WARN!! encountered a nack > message (pre_nak_long_db_search) for $Right_Nightstand. It may be > unplugged, have a burned out bulb, or this may be a new I2CS type > device that must first be manually linked to the PLM using the set > button. > 10/16/19 14:38:53 [Insteon::BaseObject] WARN: Now calling message > failure callback: &Insteon::_get_next_linkscan_failure(1) > 10/16/19 14:38:53 [Scan all link tables] WARN: failure occurred when > scanning $Right_Nightstand. Moving on... > > Has anyone seen, and come up with a resolution on this? > > Regards, > Seann > > > > > > > ________________________________________________________ > To unsubscribe from this list, go to: > https://lists.sourceforge.net/lists/listinfo/misterhouse-users<https://urldefense.proofpoint.com/v2/url?u=https-3A__lists.sourceforge.net_lists_listinfo_misterhouse-2Dusers&d=DwMFaQ&c=gRgGjJ3BkIsb5y6s49QqsA&r=0AZapnbd99a1NB2emzVyYg&m=YZ3BJ-7pIRgDpsAE2dsrKDyOuLMedP3YiCR4r_5VAms&s=h1F2sdaFnNWpa9RYbSduZ6tCOTV92U0AJsE303SlKG0&e=> > ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users<https://urldefense.proofpoint.com/v2/url?u=https-3A__lists.sourceforge.net_lists_listinfo_misterhouse-2Dusers&d=DwMFaQ&c=gRgGjJ3BkIsb5y6s49QqsA&r=0AZapnbd99a1NB2emzVyYg&m=YZ3BJ-7pIRgDpsAE2dsrKDyOuLMedP3YiCR4r_5VAms&s=h1F2sdaFnNWpa9RYbSduZ6tCOTV92U0AJsE303SlKG0&e=> ________________________________________________________ To unsubscribe from this list, go to: https://urldefense.proofpoint.com/v2/url?u=https-3A__lists.sourceforge.net_lists_listinfo_misterhouse-2Dusers&d=DwICAg&c=gRgGjJ3BkIsb5y6s49QqsA&r=0AZapnbd99a1NB2emzVyYg&m=YZ3BJ-7pIRgDpsAE2dsrKDyOuLMedP3YiCR4r_5VAms&s=h1F2sdaFnNWpa9RYbSduZ6tCOTV92U0AJsE303SlKG0&e= ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users