Re: [mh] Insteon problems with new PLM
Spencer Ryan <[email protected]>
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <CALWY-Yr9BKnU7MHK5pjcaGFYUaKfjtWCBXwYu_ujVA7LtKNXog@mail.gmail.com> |
Yeah, factory reset it again, and assuming your devices are i2cs all you should have to do is "link to interface" On Wed, Oct 16, 2019, 5:30 PM Carl McGrath <[email protected]> wrote: > I have experienced what sounds similar with KeyPadLink units, found I > had to factory reset to get them to behave and respond properly. > > On 10/16/19 4:03 PM, Seann via misterhouse-users wrote: > > All, > > I recently replaced my old, and issue prone PLM (2412S V3.1) with a > > new model, a 2413s. While running into issues that I have seen on the > > mailing list and forums before, mainly with having to manually re-link > > devices with the PLM, I came across an error that I can't find any > > data on. > > Two of my lamplinc devices refused to sync or link (manual linking > > doesn't seem to take either, have tried it two times each way, via > > link as controller in MH, and by manually on the PLM via the set > > button), and return the error "pre_nak_long_db_search" as part of the > > NACK sent back. I can't find anything at all on google for this > > specific message, so I am stumped and wondering if anyone else has > > seen this? > > The other issue I have run into is I have a Keypadlinc that is > > refusing to sync/link, but unlike the lamplinc's it doesn't return an > > actual NAK message, it just blankly NACK's anything from the new PLM, > > even after a factory reset. > > > > I am running the latest master branch code, and aside from dropped > > messages and table errors on the old PLM, things were working very > > well on my issue devices mentioned above. > > > > > > The logs for this, on debug are: > > 10/16/19 14:38:50 [Scan all link tables] Now scanning: > > $Ceiling_fan_light (3 of 15) > > 10/16/19 14:38:50 [Insteon::AllLinkDatabase] WARN The link table for > > $Ceiling_fan_light has changed. > > 10/16/19 14:38:50 [Insteon::ALDB_i2] $Ceiling_fan_light reading ALDB > > at location: 0x0000 > > 10/16/19 14:38:50 [Insteon::BaseObject] WARN!! encountered a nack > > message () for $Ceiling_fan_light. It may be unplugged, have a burned > > out bulb, or this may be a new I2CS type device that must first be > > manually linked to the PLM using the set button. > > 10/16/19 14:38:50 [Insteon::BaseObject] WARN: Now calling message > > failure callback: &Insteon::_get_next_linkscan_failure(1) > > 10/16/19 14:38:50 [Scan all link tables] WARN: failure occurred when > > scanning $Ceiling_fan_light. Moving on... > > 10/16/19 14:38:50 [Scan all link tables] Now scanning: > > $Left_Nightstand (4 of 15) > > 10/16/19 14:38:50 [Insteon::AllLinkDatabase] WARN The link table for > > $Left_Nightstand has changed. > > 10/16/19 14:38:50 [Insteon::ALDB_i2] $Left_Nightstand reading ALDB at > > location: 0x0000 > > 10/16/19 14:38:51 [Insteon::BaseInterface] DEBUG: PLM > > command:insteon_ext_received; Device command:read_write_aldb; > > type:direct; group: > > 10/16/19 14:38:52 [Insteon::BaseObject] WARN!! encountered a nack > > message (pre_nak_long_db_search) for $Left_Nightstand. It may be > > unplugged, have a burned out bulb, or this may be a new I2CS type > > device that must first be manually linked to the PLM using the set > > button. > > 10/16/19 14:38:52 [Insteon::BaseObject] WARN: Now calling message > > failure callback: &Insteon::_get_next_linkscan_failure(1) > > 10/16/19 14:38:52 [Scan all link tables] WARN: failure occurred when > > scanning $Left_Nightstand. Moving on... > > 10/16/19 14:38:52 [Scan all link tables] Now scanning: > > $Right_Nightstand (5 of 15) > > 10/16/19 14:38:52 [Insteon::AllLinkDatabase] WARN The link table for > > $Right_Nightstand has changed. > > 10/16/19 14:38:52 [Insteon::ALDB_i2] $Right_Nightstand reading ALDB > > at location: 0x0000 > > 10/16/19 14:38:52 [Insteon::BaseInterface] DEBUG: PLM > > command:insteon_ext_received; Device command:read_write_aldb; > > type:direct; group: > > 10/16/19 14:38:53 [Insteon::BaseObject] WARN!! encountered a nack > > message (pre_nak_long_db_search) for $Right_Nightstand. It may be > > unplugged, have a burned out bulb, or this may be a new I2CS type > > device that must first be manually linked to the PLM using the set > > button. > > 10/16/19 14:38:53 [Insteon::BaseObject] WARN: Now calling message > > failure callback: &Insteon::_get_next_linkscan_failure(1) > > 10/16/19 14:38:53 [Scan all link tables] WARN: failure occurred when > > scanning $Right_Nightstand. Moving on... > > > > Has anyone seen, and come up with a resolution on this? > > > > Regards, > > Seann > > > > > > > > > > > > > > ________________________________________________________ > > To unsubscribe from this list, go to: > > https://lists.sourceforge.net/lists/listinfo/misterhouse-users > > > > > > ________________________________________________________ > To unsubscribe from this list, go to: > https://lists.sourceforge.net/lists/listinfo/misterhouse-users > > ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users