Re: [mh] Solution for X10 Lamp Modules and LED flicker when on.
Rick Steeves <[email protected]>
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <[email protected]> |
I'm another X10 user who's interested. I haven't had the problem yet, but I figure it's only a matter of time. rick On 1/31/2021 11:36 AM, Giles Godart-Brown wrote: > Thanks Jim > > I've created > https://github.com/hollie/misterhouse/wiki/X10-lamp-modules-and-flickering-LEDs > with the content of this (without the diagram) > > Please could you edit it as you see fit? > > Giles > > On 31/01/2021 13:52, Jim Serack wrote: >> >> Short version: I have a solution for LED flicker X10 Lamp Modules when >> on and I’m wondering if this is a common enough to put the effort into >> a tutorial on how to fix or if everyone has moved on already. >> >> Question: Do you have this problem and do you feel it worth fixing the >> old tech? >> >> Longer version: >> >> I’ve got a house with more than a dozen X10 lamp modules (ok some >> would say a museum) that have served me well and generally meet my >> needs along with UPB, and HAI alarm and control. In total around 150 >> points of automation, monitoring and sensing of lighting, HVAC, Pool, >> Alarm, Irrigation, motorized awnings, etc. Misterhouse has been part >> of this setup throughout. >> >> So I’m not inclined to discard and replace the X10 Lamp Modules yet >> I’ve started to have more and more lamps with intermittent flicker >> during the ON state as I end up replacing incandescent bulbs with >> dimmable LED’s. >> >> I put together a test setup including a digital storage scope and >> determined the problem is that the LED bulb current sometimes (~ 5% of >> the time) drops below the TRIAC (in the lamp module) latching current >> and thus turns off: >> >> Persistent trace scope image of an LED Bulb on X10 Lamp Dimmer running >> 50% dim – dropout in Quadrant II >> >> The 6W LED Bulb current averages around 50 mA and the BTA10-400C has a >> typical IL spec of 35mA (and no maximum in the specs). I replaced the >> TRIAC with one with a IL MAX of 15 mA and the problem went away. >> >> The solution is to do a straight forward component replacement in the >> X10 Lamp Module. The BTA10-400C TRIAC in at least some brands of the >> modules can carry up to 10A (1200 watts) yet the module states 300W >> max. Replacement Triacs with the lower latching current are readily >> available up to 8 A of load (960 watts) that still exceed the 300W max >> for the module and cost < $2 each – it takes about 30 minutes to do a >> module (the first time). >> >> >> >> ________________________________________________________ >> To unsubscribe from this list, go to:https://lists.sourceforge.net/lists/listinfo/misterhouse-users >> > > > ________________________________________________________ > To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users > -- Rick Steeves https://www.irelandbybicycle.com It's all fun and games until someone ends up wearing a cone. ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users