Re: [mh] Solution for X10 Lamp Modules and LED flicker when on.
Joel Davidson via misterhouse-users <[email protected]>
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <[email protected]> |
I've still got a number of x-10 modules here as well, and it's getting tough to find incandescent bulbs for them, so this will be very helpful. Jim- do you have a part number for the triac you used in your modules? Thanks. Joel On Sun, 31 Jan 2021, it would appear that Rick Steeves wrote: > I'm another X10 user who's interested. I haven't had the problem yet, but I > figure it's only a matter of time. > > rick > > On 1/31/2021 11:36 AM, Giles Godart-Brown wrote: > > Thanks Jim > > > > I've created > > https://github.com/hollie/misterhouse/wiki/X10-lamp-modules-and-flickering-LEDs > > with the content of this (without the diagram) > > > > Please could you edit it as you see fit? > > > > Giles > > > > On 31/01/2021 13:52, Jim Serack wrote: > > > > > > Short version: I have a solution for LED flicker X10 Lamp Modules when on > > > and I?m wondering if this is a common enough to put the effort into a > > > tutorial on how to fix or if everyone has moved on already. > > > > > > Question: Do you have this problem and do you feel it worth fixing the old > > > tech? > > > > > > Longer version: > > > > > > I?ve got a house with more than a dozen X10 lamp modules (ok some would > > > say a museum) that have served me well and generally meet my needs along > > > with UPB, and HAI alarm and control. In total around 150 points of > > > automation, monitoring and sensing of lighting, HVAC, Pool, Alarm, > > > Irrigation, motorized awnings, etc. Misterhouse has been part of this > > > setup throughout. > > > > > > So I?m not inclined to discard and replace the X10 Lamp Modules yet I?ve > > > started to have more and more lamps with intermittent flicker during the > > > ON state as I end up replacing incandescent bulbs with dimmable LED?s. > > > > > > I put together a test setup including a digital storage scope and > > > determined the problem is that the LED bulb current sometimes (~ 5% of the > > > time) drops below the TRIAC (in the lamp module) latching current and thus > > > turns off: > > > > > > Persistent trace scope image of an LED Bulb on X10 Lamp Dimmer running 50% > > > dim ? dropout in Quadrant II > > > > > > The 6W LED Bulb current averages around 50 mA and the BTA10-400C has a > > > typical IL spec of 35mA (and no maximum in the specs). I replaced the > > > TRIAC with one with a IL MAX of 15 mA and the problem went away. > > > > > > The solution is to do a straight forward component replacement in the X10 > > > Lamp Module. The BTA10-400C TRIAC in at least some brands of the modules > > > can carry up to 10A (1200 watts) yet the module states 300W max. > > > Replacement Triacs with the lower latching current are readily available > > > up to 8 A of load (960 watts) that still exceed the 300W max for the > > > module and cost < $2 each ? it takes about 30 minutes to do a module (the > > > first time). > > > ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users