Re: [mh] Vista-20p or Vista-21ip
Brian M <[email protected]> Mon, 7 Feb 2022 12:58:54 -0800
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <[email protected]> |
Excellent information, Wayne. That's just what I was looking for. Thanks for posting! -Brian M. On 2/7/22 11:58 AM, Wayne Gatlin wrote: > I currently have a vista 20p, but I had a 21ip in the past. I would > suggest the 20p because with the 21ip you have to replace the whole > board when the GSM board gets too old and the providers decom the > supported tech IE: 2g. I don't know why, but this is what happened to > me with my last 21ip. With the 20p you can get an upgraded chip with > a newer version if required and use an external GSM module. If you > want to have alarm monitoring service over your wired internet > connection only (no GSM or dial up over POTS line) or you can use the > wired connection as a backup, then the 21ip is the way to go. You > can't do anything else with the wired IP connection, it will only > communicate with the total connect service. > > To interface with MH, you can get one of the AD2x interface modules > which connects like another key pad. This module will work with either > the 20p or 21ip and I assume many more. I wrote a good bit of the AD2x > interface MH code, I have been using this setup for years, and it > works well. I currently have the AD2pHAT on a Pi mounted in the alarm > panel and the Pi is just running ser2sock powered by the "DC Power > Adapter", but it looks like they have an AD2IOT which would probably > be better suited. > > -Wayne > > On Mon, Nov 29, 2021 at 11:03 PM Brian M > <[email protected] > <mailto:[email protected]>> wrote: > > Does anybody have any recent experience connecting a Honeywell/Ademco > Vista-20p or Vista-21ip alarm panel (alarm sensors, smoke sensor, > etc.) > to MH? The 20p and the 21ip are the same board except that the > 21ip has > an ethernet jack and monitoring is done via the network connection > (instead of serial, phone line, cell tower, etc.). I'd like MH to be > notified when a sensor fires. Apparently I can tell the alarm > system to > use an IP address of my choice for monitoring, but I can't find > any docs > on the network protocol is. > > I haven't bought the Vista yet, so I'm open to other products as > well, > but I don't want it to rely on outside services -- all in-house. > > Thanks everyone. > > -Brian M. > > > > ________________________________________________________ > To unsubscribe from this list, go to: > https://lists.sourceforge.net/lists/listinfo/misterhouse-users > ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users