[mh] Need a working Z-Wave configuration
Brian M <[email protected]> Sat, 10 Dec 2022 09:26:30 -0800
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <[email protected]> |
I'm hoping someone with a working Z-Wave configuration under MH will
share their relevant configuration information with me, as I can't get
mine to work.
Details:
I'm starting to dabble with Z-Wave under MH. I have an AEOTec Z-Stick
(Gen5) plugged into my Raspberry Pi. I've tested the Z-stick using the
Open Z-Wave control panel (ozwcp) installed and executed under the MH
login. It can control my one Z-Wave light switch, so I know the Z-stick
is good and the MH login has all the necessary permissions.
MH can't seem to connect to the Z-stick however. At start-up it attempts
to send a reset to the Z-Stick, but fails.
I'm running the latest MH code pulled from the master branch (last
update 10/29/2022).
In mh.private.ini I have:
ZWave_RZC0P_serial_port=/dev/ttyACM0
rzc0p_errata=4
rzc0p_retry_limit=5
rzc0p_update10=0
rzc0p_update100=1
rzc0p_update1000=1
rzc0p_timeout=10 # Tried this at 60, no difference.
rzc0p_id=001
In items.mht I have:
#Item Type Zwave ID# name groups
interface polling_interval 2way(1 or 0) resume_level
(if dimmer)
ZWAVE_APPLIANCE, 006, office_fan, All_Lights,
ZWave_RZC0P, 7, 0
Here's the log:
12/10/22 09:15:52 AM ZWave_RZC0P Info: Specified retry_limit of 5
12/10/22 09:15:52 AM ZWave_RZC0P Info: Specified timeout of 10 seconds
to Zwave interfaceM ZWave_RZC0P Debug: Writing data >DE
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: ZWave interface
timeout, cmd:>DE
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: data timeout
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: cmd timeout
12/10/22 09:15:52 AM Oops1: Use of uninitialized value in hash
element at /home/mh/mh/bin/../lib/ZWave_RZC0P.pm line 420.
12/10/22 09:15:52 AM Oops1: Use of uninitialized value $upd_count in
numeric gt (>) at /home/mh/mh/bin/../lib/ZWave_RZC0P.pm line 423.
12/10/22 09:15:52 AM Oops1: Use of uninitialized value in hash
element at /home/mh/mh/bin/../lib/ZWave_RZC0P.pm line 429.
12/10/22 09:15:52 AM Oops1: Use of uninitialized value in numeric gt
(>) at /home/mh/mh/bin/../lib/ZWave_RZC0P.pm line 429.
12/10/22 09:15:52 AM ZWave_RZC0P Adding
id:006,type:ZWAVE_APPLIANCE,inst:0 to node list
12/10/22 09:15:52 AM ZWave_RZC0P Debug: Writing data >?N006 to Zwave
interface
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: ZWave interface
timeout, cmd:>?N006
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: data timeout
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: xmit timeout
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: cmd timeout
12/10/22 09:15:52 AM ZWave_RZC0P Info: Retrying Command >?N006,
Retry Number:1 time:1670692573.43541
12/10/22 09:15:52 AM ZWave_RZC0P Debug: Writing data >?N006 to Zwave
interface
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: ZWave interface
timeout, cmd:>?N006
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: data timeout
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: xmit timeout
12/10/22 09:15:52 AM ZWave_RZC0P ZWave_RZC0P error: cmd timeout
12/10/22 09:15:52 AM ZWave_RZC0P Was in Zwave check_for_data sub for
10.0004432201385 seconds
The Oops1 errors are in the timeout handler, so they probably wouldn't
happen if the timeout didn't occur. The simple problem is that the
initial send is timing out.
It's probably something simple, like needing to declare a baud rate
(which baud and how) or something similar. Do I need to run setserial
first? Can anyone put me on the right track?
-Brian M
________________________________________________________
To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users