bug in siemens tc53 at2
"Jacob Vennervald Madsen" <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <AA6075F044E39D4DBBA876CA427A0E02057B4F@gop-server.GOP-server.local> |
Hi List I think there is a bug in the Siemens TC35 AT2 code. When a message is sent through a Siemens TC35 in PDU mode it can send three different responses: +CMGS:<mr>OK This means that the message was successfully sent. OK This means that the modem understood the command but it could not send the message. +CMS ERROR:<err> This means that the modem didn't understand the command. If I send a lot of messages back and forth on a Siemens modem some messages doesn't get sent because kannel takes the OK message as successful sending when it really should try sending again. Jacob Vennervald