bug in siemens tc53 at2

"Jacob Vennervald Madsen" <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <AA6075F044E39D4DBBA876CA427A0E02057B4F@gop-server.GOP-server.local>
Hi List

I think there is a bug in the Siemens TC35 AT2 code.
When a message is sent through a Siemens TC35 in PDU mode it can send
three different responses:

+CMGS:<mr>OK
This means that the message was successfully sent.

OK
This means that the modem understood the command but it could not send
the message.

+CMS ERROR:<err>
This means that the modem didn't understand the command.

If I send a lot of messages back and forth on a Siemens modem some
messages doesn't get sent because kannel takes the OK message as
successful sending when it really should try sending again.

Jacob Vennervald