RE: bug in siemens tc53 at2
"Jacob Vennervald Madsen" <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <AA6075F044E39D4DBBA876CA427A0E0203D838@gop-server.GOP-server.local> |
Sorry the subject should of course be "TC35". > -----Original Message----- > From: Jacob Vennervald Madsen > Sent: 1. maj 2002 10:49 > To: [email protected] > Subject: bug in siemens tc53 at2 > > > Hi List > > I think there is a bug in the Siemens TC35 AT2 code. > When a message is sent through a Siemens TC35 in PDU mode it can send > three different responses: > > +CMGS:<mr>OK > This means that the message was successfully sent. > > OK > This means that the modem understood the command but it could not send > the message. > > +CMS ERROR:<err> > This means that the modem didn't understand the command. > > If I send a lot of messages back and forth on a Siemens modem some > messages doesn't get sent because kannel takes the OK message as > successful sending when it really should try sending again. > > Jacob Vennervald > >