Re: Siemens OTA (SEO) with Kannel?

[email protected]
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
Hi Dominik,

When sending Siemens SEO formatted message, you do _not_ use UDH at all. 
TP-UDHI must be set as 0 (thus TP-UDH does not exist at the SMS). Also TP-DCS 
must be set as 0xF5 (payload is coded as 8 bit data).

Siemes SEO format has nothing to do with committee work EMS format.

I'm sorry I do not know how to send such message over Kannel.

With best regards,

-make

 Markku Luosto
 Jippii



| From:    Dominik Simon <[email protected]>
| Date:    Sat, 08 Mar 2003 15:17:42 +0100
| 
| Hi Soren,
| 
| here is my specification of siemens-ota (seo), I use:
| 
| - - - -
| 
| 5 [2F 2F 53 45 4F] - Identifier ASCII "//SEO"
| 1 [01] - Version 1
| 2 [67 00] - DataSize = 103 Byte
| 4 [79 07 00 00] - Referenz-ID
| 2 [01 00] - ActPacketNumber = 1
| 2 [08 00] - NumberOfPackets = 8
| 4 [EE 02 00 00] - ObjectSize = 750 Byte
| 4 [03 62 6D 70] - ObjectType = 3 "bmp"
| 13 [OC 4F 70 65 72 61 74 6F 72 2E 62 6D 70] - ObjectName = 12 "Operator.bmp"
| 103 [70 42 4D ...] Data of the Bitmap in BMP-Format
| = 140 Bytes (if the last sms is less, you have to fill out with 00 (zero).
| 
| - - - -
| 
| If you have a look on my seo-example, here I split and tell you more about
| the first sms:
| 
| 2F2F53454F       = //SEO
| 
| 01               = Seo-Version 1
| 
| 6600             = my Data-Size is 102 Byte
| 
| 2664673E         = my ID of the seo-sms (must be the same in every sms)
| 
| 0100             = message-number 1
| 
| 0500             = of 5 messages
| 
| C3010000         = 451 byte data-size (here from my midi)
| 
| 036D6964         = 3 number of letters / BMP
| 
| 0D756E646572626572672E6D6964 = 13 number of letters / UNDERBERG.MID
| 
| 4D546864000000060001000201E04D54726B0000004700FF0314417564696F496E7374202031
| 2A6B6F706965727400FF01124445564943453D47454E4552414C2E4D445600FF580404022408
| 00FF5902000000FF5103087A2300FF2F004D54726B0000015E00
| = DATA of the midifile
| 
| - - - -
| 
| Now I want to send this seo-string to my kannel-gateway, as udh-string
| - but it only works with ems-messages :-(( no siemens.
| 
| Thanks for your help!
| 
| -- 
| Best regards,
|  Dominik                          mailto:[email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.