Re: electrical problems with Galvanic Skin Response circuit ( GSR SCL )
Steffen <[email protected]>
| Newsgroups | gmane.comp.science.openeeg.general |
|---|---|
| Message-ID | <[email protected]> |
Hi Stefan, thanks for your extensive and quick answer. I already swapped the input pins 2 and 3 and i also choosed a 25k resistor --> Gain=5. The problem is the mains hum (att. hum.jpg), which is so big, that i cant recognize any change in the skin conductance, only little changes in the shape of the signal. With an 1Mohm potentiometer as a replacement for the skin all things are fine and i can see a raising DC-Voltage on the oscilloscope. > I just checked my archive, although I have more than one version of the > schematic, they all show R25=1K. You are correct that 1K gives a gain of > 101. I scratched out my one and only prototype of this circuit and see > that I used a 1003 resistor in that position, i.e. a 100K which gives a > gain of 2. Does 1003 resistor mean 100k? Regards Steffen ------------------------------------------------------------------------------ Learn Graph Databases - Download FREE O'Reilly Book "Graph Databases" is the definitive new guide to graph databases and their applications. Written by three acclaimed leaders in the field, this first edition is now available. Download your free book today! http://p.sf.net/sfu/13534_NeoTech