Hi Stefan, Maybe i found the reason for the behaviour of the AD623, that the outputvoltage was always to little. In the datasheet of the AD623 you can see a limitation of the outputvoltage depending on the common-input mode. In my understanding we deal with voltages around 500mV Vin- : 500mV Vin+: 600mV So the common-mode input voltage is (500mV+600mV) / 2= 550mV. According to the diagram the maximum output Voltage then is about 2,2V. To that i have two questions: 1. Do i have to set another opamp after the AD623 to get a full range of 0-5V for the AD-converter? Do i have to make sure, that the output voltage is always lower than the max. Voltage from the diagram? 2. Or do i have to make sure the common-mode input is exactly 1,8V, to get max. 5V Output Voltage belong to the diagram? But is this possible with 500mV Vref? The changing skin resistance would change the common-mode inut voltage too, isnt it? But how is it possible that i got 4,18V at the output from AD623 with 0,5V at Vin- and 1,55V at Vin+? The common-mode input voltage is (500mV+1550mV) / 2= 1025mV. According to the diagram the maximum output Voltage should be smaller than 3,1V. Or do i misunderstand the diagram. Regards Steffen ------------------------------------------------------------------------------ Is your legacy SCM system holding you back? Join Perforce May 7 to find out: • 3 signs your SCM is hindering your productivity • Requirements for releasing software faster • Expert tips and advice for migrating your SCM now http://p.sf.net/sfu/perforce
Output_Voltage.jpg
(image/jpeg, 45.3 KB) - not displayed