Re: System Link
"Michael J. Raber" <[email protected]>
| Newsgroups | gmane.comp.systems.as400.mapics |
|---|---|
| Message-ID | <[email protected]> |
Hi Iain, after many tests - also with loading of master data ITEMAS and ITEMBL - I just finished a project for a customer. We are using SystemLink for loading CustomerOrder in a german R7.8 environment. I used the WSDL and Axis 1.2 (do not use 2.0 - there are problems to expect) to build Java-Code and it works fine. Performance is similar to the COM-Offline-Load. Processing need a few seconds to connect, load order and disconnect. But I agree Kevin, that you should think about using AuxiliaryServer. Actually we prepare a project for a customer project using LPI (the "green" interface to SystemLink). We had some problems during the first steps but most of them were fixed by ourselves or InforSupport. So you should not hesitate to use this new technology. For more detailed questions you may contact me by the website: http://www.mjraber.de/index.php?option=com_contact&view=contact&id=1&Itemid=56 Best regards Michael Am 13.06.2011 13:40, schrieb Iain Wilson: > Hi All > > Just bought the Flex offering that contains (amongst other modules) System > Link. Is there anyone out there using System Link to perform any data > manipulation (imports/exports/modification) with XA. We would like to > replace our current offline load processes it > > Item Master/Balance offline loads > COM order offline loads > REP Routing offline loads > PDM Product structure offline loads. > > We are at XA R7.8 and will move to R9.1 mid next year. > > I am aware that these offline loads will disappear at R10 and we will have > to rewrite by then anyway. > > > I would be interested in any comments from systems people regarding setup, > performance, problems or any other comments > > Many thanks > > Iain > > > > > > This e-mail and any attachments contain material that is confidential for the sole use of the intended recipient. Any review, reliance or distribution by others or forwarding without express permission is strictly prohibited. If you are not the intended recipient, please contact the sender and delete all copies. > > Tokheim UK LTD. Registered in Scotland No. 58090 > Registered Office: Exchange Tower, 19 Canning Street, Edinburgh EH3 8EH > _______________________________________________ > This is the MAPICS ERP System Discussion (MAPICS-L) mailing list > To post a message email: MAPICS-L-Zwy7GipZuJhWk0Htik3J/[email protected] > To subscribe, unsubscribe, or change list options, > visit: http://lists.midrange.com/mailman/listinfo/mapics-l > or email: MAPICS-L-request-Zwy7GipZuJhWk0Htik3J/[email protected] > Before posting, please take a moment to review the archives > at http://archive.midrange.com/mapics-l. > _______________________________________________ This is the MAPICS ERP System Discussion (MAPICS-L) mailing list To post a message email: MAPICS-L-Zwy7GipZuJhWk0Htik3J/[email protected] To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/mapics-l or email: MAPICS-L-request-Zwy7GipZuJhWk0Htik3J/[email protected] Before posting, please take a moment to review the archives at http://archive.midrange.com/mapics-l.