Re: Problem with Zoom USB modem

David Denney <[email protected]>
Newsgroups gmane.comp.telephony.fax.hylafax.user
Message-ID <CAP5AYSVV==i6ahQcMpKNqkwad7oLzMFf3mFQji8O9Q=0p7=Hyg@mail.gmail.com>
As to the recvq, I did chmod it to change two received files that were
there (probably incorrectly) What should the recvq be set to?

I have removed the AT&F line and changed the FlowControl to xonxoff and
restarted. Now cu shows ATZ and AT&F behaving correctly (get OK with both
commands). The FlowControl set was the result of faxaddmodem being ran.
Maybe I chose unwisely there.

Once I get the recvq fixed, I will retest.

David


On Fri, Oct 23, 2015 at 11:02 AM, Lee Howard <[email protected]>
wrote:

> On 10/23/2015 08:54 AM, David Denney wrote:
>
> Oct 23 11:49:08 CTIKY-FAX FaxGetty[1347]: recvq/seqf: open: Permission
>> denied
>> Oct 23 11:49:08 CTIKY-FAX FaxGetty[1347]: RECV FAX: Unable to create temp
>> file for received data: Unable to open sequence number file recvq/seqf;
>> Permission denied.
>>
>
> It's unrelated, but did you notice this above?  Your
> /var/spool/hylafax/recvq/seqf file has the wrong permissions.  Did you
> chown it at some point?  This should be fixed.
>
> Oct 23 11:49:11 CTIKY-FAX FaxGetty[1347]: MODEM set DTR OFF
>> Oct 23 11:49:12 CTIKY-FAX FaxGetty[1347]: MODEM set DTR OFF
>> Oct 23 11:49:12 CTIKY-FAX FaxGetty[1347]: DELAY 75 ms
>> Oct 23 11:49:12 CTIKY-FAX FaxGetty[1347]: MODEM set DTR ON
>> Oct 23 11:49:12 CTIKY-FAX FaxGetty[1347]: DELAY 2600 ms
>> Oct 23 11:49:15 CTIKY-FAX FaxGetty[1347]: MODEM set baud rate: 19200
>> baud, input flow RTS/CTS, output flow RTS/CTS
>> Oct 23 11:49:15 CTIKY-FAX FaxGetty[1347]: DELAY 10 ms
>> Oct 23 11:49:15 CTIKY-FAX FaxGetty[1347]: MODEM flush i/o
>> Oct 23 11:49:15 CTIKY-FAX FaxGetty[1347]: <-- [5:AT&F\r]
>> Oct 23 11:49:15 CTIKY-FAX FaxGetty[1347]: --> [5:ERROR]
>>
>
> So, it's doing the same thing with AT&F as it did with ATZ.
>
> Use cu or minicom to verify, but you're going to need to find some command
> to tell the modem to reset itself.
>
> However... you're using "ModemFlow: rtscts", and the problem may actually
> be that it should be "xonxoff", instead.
>
> So the "ERROR" may be due to the modem getting the wrong data from the
> DTE.  In other words, we send "AT&F" or "ATZ", but then the modem gets
> something else because the data got corrupted in the serial path due to a
> flow control problem (although that should not come into play with the AT
> commands).
>
> I guess if all else fails you could disable resetting entirely with:
>
> ModemSoftResetCmd: AT
>
> But that's likely to cause other issues later.
>
> Thanks,
>