Re: chrony (or I210) loses PHC refclock PPS signal?
Fabian <[email protected]>
| Newsgroups | gmane.comp.time.chrony.user |
|---|---|
| Message-ID | <[email protected]> |
It's about 30cm long, with PPS and GND. For GND I used the pin on the I210. The cables are simple jumper cables unfortunateley, no shielding. Am 29.03.2022 um 09:38 schrieb Miroslav Lichvar: > On Sat, Mar 26, 2022 at 09:59:52PM +0100, Fabian wrote: >> I think I might have found the problem, but unsure on how to fix that. >> In the room there is a fluorescent lamp, whenever someone switches on the >> light, there is a chance the PPS input on the card will stop. > > How long is the cable and is it electrically terminated? > > I have seen the PPS timestamping on I210 to randomly stop working when > reconnecting between different GPS units. I suspect it happens when > the hardware gets multiple pulses too close to each other. I can > reproduce it by configuring the GPS with the CFG-TP5 command to > generate pulses at a very high rate. > > There seem to be two different failure modes. With one it is sufficient > to restart chronyd, but the other one requires reloading of the driver. > I looked at the driver source code for any clues, but didn't see > anything. > -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]