Re: VECTOR: G05-802
"Matt Rossiter" <[email protected]> Sat, 11 Jun 2005 15:25:58 -0700
| Newsgroups | gmane.games.arcade.vector |
|---|---|
| Message-ID | <001701c56ed4$8b73c770$022d10ac@mrossiterverio> |
I just posted a solution to a similar problem yesterday. :) Pull out resistor R518 (470K) and replace it with something of less resistance. I would recommend something between 350K to 400K (1/2 Watt). This gave me alot more control over the brightness. Also, be sure your voltages are all correct, make sure you have about 90v on pin 1 of the P500 connector. That solved my problem anyway, yours might be something different. My game has been running for a day now and no problems yet. Matt ----- Original Message ----- From: "Tom Bombaci" <[email protected]> To: <[email protected]> Sent: Saturday, June 11, 2005 2:13 PM Subject: VECTOR: G05-802 > I am troubleshooting a G05-802. I have retrace lines that will not go away. > The center dot is very bright as well. I have installed a cap kit from bob, > I have replaced both the brightness and contrast POTS and I just replaced > q504. > > After the cap kit, the contrast POT did nothing. After replacing both POTS, > the contrast POT still does nothing in terms of adjusting the contrast. > > Thoughts? > > Regards, > Tom > > -------------------------------------------------------------------------- - > ** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org > ** Please direct other questions, comments, or problems to [email protected] > >