Re: VECTOR: G05-802

"Matt Rossiter" <[email protected]> Sat, 11 Jun 2005 15:25:58 -0700
Newsgroups gmane.games.arcade.vector
Message-ID <001701c56ed4$8b73c770$022d10ac@mrossiterverio>
I just posted a solution to a similar problem yesterday.  :)  Pull out
resistor R518 (470K) and replace it with something of less resistance.  I
would recommend something between 350K to 400K (1/2 Watt).  This gave me
alot more control over the brightness.

Also, be sure your voltages are all correct, make sure you have about 90v on
pin 1 of the P500 connector.  That solved my problem anyway, yours might be
something different.  My game has been running for a day now and no problems
yet.

Matt



----- Original Message ----- 
From: "Tom Bombaci" <[email protected]>
To: <[email protected]>
Sent: Saturday, June 11, 2005 2:13 PM
Subject: VECTOR: G05-802


> I am troubleshooting a G05-802. I have retrace lines that will not go
away.
> The center dot is very bright as well. I have installed a cap kit from
bob,
> I have replaced both the brightness and contrast POTS and I just replaced
> q504.
>
> After the cap kit, the contrast POT did nothing. After replacing both
POTS,
> the contrast POT still does nothing in terms of adjusting the contrast.
>
> Thoughts?
>
> Regards,
> Tom
>
> --------------------------------------------------------------------------
-
> ** Unsubscribe, subscribe, or view the archives at
http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to
[email protected]
>
>