Re: VECTOR: Amplifone HV problems

"MyPearl" <[email protected]>
Newsgroups gmane.games.arcade.vector
Message-ID <002201c486eb$c1eda4f0$1200a8c0@avpc>
In my experience, when the -24V regulator fails, you'll get low HV (like in
this case) and ofcourse the big resistor which is over the regulator will
fry.

Mendel


----- Original Message -----
From: "Christopher X. Candreva" <[email protected]>
To: <[email protected]>
Sent: Friday, August 20, 2004 8:16 PM
Subject: Re: VECTOR: Amplifone HV problems


> On Fri, 20 Aug 2004 [email protected] wrote:
>
> > A few months back, I wrote about the 19" Amp in my Quantum being very
very
> > dim, and very out of focus.  (it was previousely working just great).
> > Since then, I haven't had much time to work on it due to travelling a
lot
> > for work.  Last night, I decided to get back to it.  Let me document as
> > many details as I can:
>
> Simple problem first -- have you checked the focus wire, and actually the
> four wires to the focus/brightness block ?  They sometimes break off
inside
> the rubber boot.
>
> I would start with those, and all the wires in the harness, especially
since
> you say you have been moving it between 2 games.
>
>
> ==========================================================
> Chris Candreva  -- [email protected] -- (914) 967-7816
> WestNet Internet Services of Westchester
> http://www.westnet.com/
> --------------------------------------------------------------------------
-
> ** Unsubscribe, subscribe, or view the archives at
http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to
[email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.