Issue TBD: Error in Radius VSA to Diameter Vendor AVP conversion in NASREQ
Submitter name: Mikko Aittola
Submitter email address: [email protected]
Date first submitted: 14.12.2004
Reference:
Document: nasreq
Comment type: T
Priority:
Section: 9.6.2
Rationale/Explanation of issue:
According to Section 9.6.2. in NASREQ Diameter AVP length field includes
padding. According to RFC 3588 AVP length field does not include
padding.
Text from NASREQ:
> 9.6.2. Forwarding a RADIUS VSA to a Diameter Vendor AVP
>
>
> The Diameter AVP will consist of the following fields;
> Diameter Flags: V=1, M=0, P=0
> Diameter Vendor code = RADIUS VSA Vendor code
> Diameter AVP code = RADIUS VSA Vendor type code
> Diameter AVP length = length of AVP (header + data + padding)
> Diameter Data = RADIUS VSA vendor data
Requested change:
Diameter AVP length = length of AVP (header + data)
BR,
Mikko
lmpx.com only provides a reader for public news (NNTP) servers. It is not
affiliated with the servers or forums shown here and is not responsible for
the content of articles, which is written by their respective authors.