RE: RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comm ent 13)
"Kumar, Satish" <[email protected]> Tue, 13 Sep 2005 15:21:19 -0500
| Newsgroups | gmane.ietf.ipcdn |
|---|---|
| Message-ID | <[email protected]> |
To avoid confusion, I would recommend to have the red(new) text above the sentence " If this object is set to 'false'..." Thx, Satish ________________________________ From: [email protected] [mailto:[email protected]] On Behalf Of Eugene Nechamkin Sent: Monday, September 12, 2005 4:05 PM To: Wijnen, Bert (Bert); Jean-Francois Mule; Ipcdn (E-mail) Cc: Richard Woundy @ Comcast Subject: [ipcdn] RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comm ent 13) > Maybe add some of that explanation to teh DESCRIPTION clause then. PROPOSED: modify the description clause to the following (mods are in red): DESCRIPTION " This object contains the MTA Admin Status of this device. If this object is set to 'true', the MTA is administratively enabled and the MTA MUST be able to interact with the PacketCable entities such as CMS, Provisioning Server, KDC, and other MTAs and MGs on all PacketCable interfaces. If this object is set to 'false', the MTA is administratively disabled and the MTA MUST perform the following actions for all endpoints: - shutdown all media sessions if present, - shutdown NCS signaling by following the Restart in Progress procedures in the PacketCable NCS specification. MTA must execute all actions required to enable/disable the telephony services for all endpoints immediately upon receipt of the SNMP SET operation. Additionally, the MTA MUST maintain the SNMP Interface For management and also SNMP Key management interface. Also, the MTA MUST NOT continue Kerberized key management with CMSes until this object is set to 'true'. Note: MTAs MUST renew the CMS Kerberos tickets according to the PacketCable Security or IPCablecom Specification." Would this modification address your concern ? Eugene. ________________________________ From: Wijnen, Bert (Bert) [mailto:[email protected]] Sent: Monday, September 12, 2005 2:03 PM To: Eugene Nechamkin; Jean-Francois Mule; Ipcdn (E-mail) Cc: Richard Woundy @ Comcast Subject: RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comm ent 13) Maybe add some of that explanation to teh DESCRIPTION clause then. Bert -----Original Message----- From: Eugene Nechamkin [mailto:[email protected]] Sent: Monday, September 12, 2005 22:19 To: Wijnen, Bert (Bert); Jean-Francois Mule; Ipcdn (E-mail) Cc: Richard Woundy @ Comcast Subject: RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comm ent 13) > For example, if I set AdminStatus to "enable", and if the device > seems unable to do so now, then I would still want the device to > try and do it as soon as it can. This example tells me where the disconnection might be. Let me try once more: the PacketCable Provisioning Specification prohibits the conditions when "the device seems unable to do so now". As soon as the EMTA receives the SNMP SET with "pktcMtaDevEnabled" being set to true/false, the device must and is always capable of enabling/disabling the telephony services on the EMTA. So, there is no scenario which can make "the device to try and do it as soon as it can" as the device would have executed all actions required by the corresponding Admin state upon SNMP SET operation. The conditions of your concern cannot happen in PacketCable environment with PacketCable compliant EMTA device. Please elaborate if this still does no cover your concerns on this subject. Eugene. ________________________________ From: Wijnen, Bert (Bert) [mailto:[email protected]] Sent: Monday, September 12, 2005 12:53 PM To: Eugene Nechamkin; Jean-Francois Mule; Ipcdn (E-mail) Cc: Richard Woundy @ Comcast Subject: RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comm ent 13) Inline -----Original Message----- From: Eugene Nechamkin [mailto:[email protected]] Sent: Monday, September 12, 2005 21:24 To: Wijnen, Bert (Bert); Jean-Francois Mule; Ipcdn (E-mail) Cc: Richard Woundy @ Comcast Subject: RE: AD Review: draft06 draft-ietf-ipcdn-pktc-mtamib-06.txt ( Comment 13) Because the message is becoming too big I am separating the responses for each comment for better trackability (also modifying the title slightly). # Comment 13 > - For pktcMtaDevEnabled a better name woul probably be > pktcMtaDevAdministrativelyEnabled > And how is the NMS going to see what the real Operational status is? > Is a AdminStatus and OperStatus (as in IF-MIB) not more appropriate? Proposed resolution: no action In general, we agree with the comment and our first reaction was, yes, let's rename it and add an operStatus one. But after looking at its definition in more details, syntax (ThruthValue) and after c onsidering a new operStatus object, we think that: - pktcMtaDevEnabled is both an admin and operational status object, hence the name is probably ok, - it returns the operational status of the enable/disable switch when read. Our proposal, after reviewing your comment is still to leave it as-is. Is this ok? if not, can you elaborate? > bw: The issue is that if you use one single object for both the admin's desire of the status and > at the same time for the actual operational status, then it gets difficult. > If you issue an SNMP SET to enable, then if you accept it, then that means that the value > is to be changed to enabled. If however the value then later changes, then I bet that the > management station is at least very surprised. It is not for nothing that the IF-MIB (after a long > experience) has chosed to haev a Admin and Operational status in two separate objects. Let me put some more clarification on the issue which may address your general concern with the Admin and Operational Status separation. One of the reasons it would make sense to separate Admin and Operational status is the potentail delay between the the SNMP SET changing the Admin Status and actual Operational status of the device including the case when the device might be not able to set the corresponding Admin status for some reasons internal to the device. In case of EMTA Enabling/Disabling, the PacketCable Provisioning spec does not allow such delays and requires the EMTA to disable/enable the Telephony Services on the EMTA with very minimal delay (if at all). Hence, from the operational prosective, the separation of the Admin and Operational Statuses in PacketCable environment does not seem to be required. Hope this clarifies. Please elaborate further otherwise. Jean-Francois and Eugene. bw: nope it does not clarify (at least not for me). I always see a difference between what an operator wants/intends (i.e. AdminStatus) and what the device was actually able to do or has done (i.e. OperStatus). The timing as to how fast the device/software has to do it has nothing to do with it it in my view. For example, if I set AdminStatus to "enable", and if the device seems unable to do so now, then I would still want the device to try and do it as soon as it can. Bert _______________________________________________ IPCDN mailing list [email protected] https://www1.ietf.org/mailman/listinfo/ipcdn