Re: Portal group discovery

William Studenmund <[email protected]>
Newsgroups gmane.ietf.ips
Message-ID <[email protected]>
On Oct 3, 2006, at 4:04 AM, Dan Bar Dov wrote:

> It is true that you cannot run two active connections in the
> same session when going through two routers.
> However, is it not possible to have a single active connection,
> and fail-over to a new (or a standby) connection ?

The problem is that putting both routers in the same Target Portal  
Group (TPG) means exactly that the initiator CAN have two active  
connections, in the same session, through the two portals.

So why do you want them in the same portal group? Why not just give  
each router a different TPG and be done with it?

Take care,

Bill

_______________________________________________
Ips mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/ips