Observed events question
"Tamar Nemet" <[email protected]>
| Newsgroups | gmane.ietf.megaco |
|---|---|
| Message-ID | <[email protected]> |
Hi,
Please look at the following megaco messages:
MGC -> MG:
T=22127{C=3983{S=e1/05/5{AT{}}},C=-{MF=e1/05/5{E=8591{bcas/sz,bcas/casf,
icas/casf},SG{icas/rlg},M{O{MO=IN}}}}}
MG -> MGC: T=22129{C=*{S=e1/05/5{AT{}}},C=-{MF=e1/05/5{SG,M{O{MO=IN}}}}}
MG -> MGC: T=233{C=-{N=E1/05/5{OE=8591{20080811T00550054:BCAS/SZ}}}}
MGC reply to MG: P=233{C=-{N=e1/05/5{ER=410{"Unknown Request ID"}}}}
In the second message there is Subtract command that delete all the
signals (SG) but there is nothing regarding requested events, so the MG
still wait for the requested events from the first message.
When the MG send Notify with the observed event (in the third message) ,
the MGC answer with Unknown Request ID.
We don't understand why this is an Unknown Request ID, this is the last
one that the MGC asked and nothing canceled this request ID.
Can you explain please ?
Thanks,
Tamar
_______________________________________________
Megaco mailing list
[email protected]
https://www.ietf.org/mailman/listinfo/megaco