Re: M3UA: Synchronizing DPC availability state between ASPs in the same AS

"Brian F. G. Bidulock" <[email protected]> Mon, 10 Apr 2017 13:51:04 -0600
Newsgroups gmane.ietf.sigtran
Organization http://www.openss7.org/
Message-ID <[email protected]>
Dan,

Brian F. G. Bidulock wrote:       (Mon, 10 Apr 2017 13:41:19)
> 
> So, yes and no, you may have to correlate the receipt of
> DUNA, DAVA, DRST, SCON at any ASP across all ASPs active
> for the AS (if the SG does not broadcast); however, you
> should never have to do so in response to DAUD.
> 

See, for example, RFC 4666/5.4 Auditing Examples.  You
will see that all transactions are between ASP and SGP,
not between AS and SG.

-- 
Brian F. G. Bidulock
[email protected]
http://www.openss7.com/