Re: [M2UA]Clarify M2UA flow control/congestion procedure

"Brian F. G. Bidulock" <[email protected]>
Newsgroups gmane.ietf.sigtran
Organization http://www.openss7.org/
Message-ID <[email protected]>
Steven,

Some early implementations of SS7 link hardware could not receive
at anything close to 1 Erlang and would generate SIB at regular
inteverals to throttle receive traffic down to a dribble while
still maintaining conformance with specifications.  A way to keep
these poor implementations out of the network was to impose a
network-specific requirement that no signalling link generate SIB.
Some specifications never removed the requirement over the years.

--brian

ZHOU Minggang wrote:                (Fri, 03 Jul 2009 14:02:27)
> Hi Brian,
> 
> Thanks a lot for your clarfication! 
> One more question:  Why do some operators require that SS7 equipment
> not issue SIB, for business reason or else?
> 
> Best regards, 
> Steven

-- 
Brian F. G. Bidulock
[email protected]
http://www.openss7.org/