Re: VRRP - Multiple Masters Question

Mukesh Gupta <[email protected]>
Newsgroups gmane.ietf.vrrp
Organization Tropos Networks
Message-ID <[email protected]>
> a) discard (and log an error) if the value advertised 
>    in the VRRP message disagrees with your configured 
>    value for hello timer.... this is what is currently
>    specified
> 
> b) use the interval advertised by the master, for as long 
>    as it is master

I would vote for option b.

> If we switch to b), then another decision is whether that 
> is configured misconfiguration or not, i.e., if an error 
> should be logged.

Yes !

Is there any case where having different advertisement intervals
on different nodes will be useful?  If not, it should be considered
a misconfiguration but handled gracefully !

We are waiting for another update of the VRRP for IPv6 draft
to address IESG's comments.  We still have some time to pitch
in this change if the WG agrees to do this !

- Mukesh