Re: Siemens MC35i
Daniele Forsi <[email protected]> Sun, 3 Aug 2014 22:09:40 +0200
| Newsgroups | gmane.linux.drivers.gnokii |
|---|---|
| Message-ID | <CAN_we7PUZycSYH7b9m+Gd5K1B_NEesaL3BBEN6VYXQwXt-OcjQ@mail.gmail.com> |
2014-08-03 21:40 GMT+02:00 Peter Øgaard Meyland: > Hmm, could it be a problem with the terminal. I.e. an unsupported or missing > function in the MC35i firmware?? yes, that's most likely, change debug to on in your config (it is off by default): [logging] # where to log the debug output (on: stderr, off: /dev/null) debug = on then repeat the command, it will show if the terminal doesn't know the command or if libgnokii doesn't know how to handle the answer (and in fact now I see that it still doen'st *parse* this answer, but you should get a success without number as you noted, not a failure, if the phone supports AT+CCFC) according to the standard document GSM 02.30, call diversions are handled optionally also as part of ATD with the same syntax you use on a phone such as ATD**61*+1234567890*11*25# -- Daniele Forsi _______________________________________________ gnokii-users mailing list [email protected] https://lists.nongnu.org/mailman/listinfo/gnokii-users