RE: Bizarre Linksys PCMPC200 problem
Donald Becker <[email protected]> Tue, 6 May 2003 01:08:27 -0400 (EDT)
| Newsgroups | gmane.linux.drivers.tulip.general |
|---|---|
| Message-ID | <[email protected]> |
On Tue, 6 May 2003, Matthijs Vrolijk wrote: > Got it fixed! Ignore my last. > > Seemed to be a simple mismatch of PCI id's. My Linksys has manufacturer > id 1737, device ab08. I noticed in tulip.c > That there is a linksys with device id ab08, but with major id 13d1 (on > line 412). By simply changing 13d1 to 1737 and recompiling, it now works > like a dream! I missed that it was a mix of the existing Linksys vendor and device IDs, but that the combination was not in the list. I've updated the tulip-diag.c program ftp://ftp.scyld.com/pub/diag/tulip-diag.c The next tulip driver release will have the new IDs as well. -- Donald Becker [email protected] Scyld Computing Corporation http://www.scyld.com 914 Bay Ridge Road, Suite 220 Scyld Beowulf cluster system Annapolis MD 21403 410-990-9993 _______________________________________________ tulip mailing list, [email protected] To change to digest mode or unsubscribe visit http://www.scyld.com/mailman/listinfo/tulip