Re: 3c905c hang (part 2)
Donald Becker <[email protected]>
| Newsgroups | gmane.linux.drivers.vortex.devel |
|---|---|
| Message-ID | <[email protected]> |
On Fri, 10 Jan 2003, Kambo Lohan wrote: > We tried the .99Y final 3c59x.c and still the same problem. I have included > more diagnostic info. We ran it with debug=4 and verified the vortex timer > is still firing every minute. However, the card stays hung and needs a > down/up. So for the moment we are running it with max_interrupt_work=1000 > as a workaround. > > vortex-diag.c:v2.04 1/8/2001 Donald Becker ([email protected]) > Index #1: Found a 3c905C Tornado 100baseTx adapter at 0xdc00. > Transceiver/media interfaces available: 100baseTx 10baseT. > Transceiver type in use: Autonegotiate. Looks good so far. > MAC settings: full-duplex. Are you forcing full duplex? > Parsing the EEPROM of a 3Com Vortex/Boomerang: > 3Com Node Address 00:04:75:71:4A:6A (used as a unique ID only). > OEM Station address 00:04:75:71:4A:6A (used as the ethernet address). > Manufacture date (MM/DD/YYYY) 8/27/2001, division H, product SY. Nothing unusual there. > MII PHY 0 at #1 transceiver registers: > 0000 0000 0000 0000 0000 0000 0000 0000 Now this is curious! The transceiver is only partially working! What are your power supply voltages? > 01:0b.0 Ethernet controller: 3Com Corporation 3c905C-TX [Fast Etherlink] > (rev 78) > Subsystem: 3Com Corporation: Unknown device 1000 -- Donald Becker [email protected] Scyld Computing Corporation http://www.scyld.com 410 Severn Ave. Suite 210 Scyld Beowulf cluster system Annapolis MD 21403 410-990-9993 _______________________________________________ vortex mailing list [email protected] http://www.scyld.com/mailman/listinfo/vortex