Re: BMC and NIC #1 interaction
Chris Adams <[email protected]>
| Newsgroups | gmane.linux.hardware.dell.poweredge |
|---|---|
| Message-ID | <[email protected]> |
Once upon a time, Ruben Laban <[email protected]> said: > Unfortunately, at this point em1 was the only interface with an IP > configured and thus lost my SSH connection. Luckily I had finally > managed to get SOL console redirection operational. However, when I > tried to open SOL connection all I got was timeouts. It seemed that the > BMC had dropped off the network as well. Once I got a colleague to bring > up em1 again, the BMC also started working again. > > Is this expected behavior?? It seems to be, yes. If the OS sets the link PHY down, the BMC is not smart enough to override it. I've had other systems with a shared NIC for OS and IPMI, and they handled that, but all the Dells I've tried with a shared NIC work this way. -- Chris Adams <[email protected]>