Re: PE R620, DSU and USB issue

Henrik Schmiediche <[email protected]>
Newsgroups gmane.linux.hardware.dell.poweredge
Message-ID <[email protected]>
Thank you. This fixed this issue!

A second issue has appeared. We have multiple R610's with 48GB of RAM 
each. When I try to update them I get the error:

*Enough contiguous physical memory is not available to perform the BIOS 
update running under**
**  this Operating System. Reboot and try again.*

(See below.) Any ideas how to fix this? 48GB should be enough memory and 
the system is quiescent with nothing running. It does say something 
about*"contiguous physical memory", *but I am not sure how to address 
that issue.

Regards,
       - Henrik*
*
---------------------------------------------------------------------
]# dsu --non-interactive
Verifying catalog installation ...
Installing catalog from repository ...
Verifying inventory collector installation ...
Getting System Inventory...
Determining Applicable Updates...
Installing R610_BIOS_C6MRW_LN_6.4.0...
Collecting inventory...
....
Running validation...

BIOS

The version of this Update Package is newer than the currently installed 
version.
Software application name: BIOS
Package version: 6.4.0
Installed version: 6.3.0

Executing update...
WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE 
UPDATE IS IN PROGRESS.
THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE!
.............................................
Device: BIOS
   Application: BIOS
   Enough contiguous physical memory is not available to perform the 
BIOS update running under
   this Operating System. Reboot and try again.

R610_BIOS_C6MRW_LN_6.4.0 could not be installed

Done! Please run 'dsu --inventory' to check the inventory

---------------------------------------------------------------------

On 3/16/2016 4:39 AM, [email protected] wrote:
>
> *Dell - Internal Use - Confidential *
>
> Hi Henrik,
>
> Yeah this is a known issue in DUP, which got fixed in latest one.
>
> Here the DUP is checking for usb-storage driver whether its loaded or 
> NOT, if NOT they are just quitting as reported below.
>
> Meanwhile I would request you to use the workaround as described below.
>
> Workaround:
>
> 1.Modprobe usb-storage
>
> 2.Install the Diagnostics_Application_5W2KP_LN64_OSC_1.1_X10-00
>
> Regards
>
> Balaji Singh
>
>
> ----------------------------------------------------------------------
>
> Message: 1
> Date: Tue, 15 Mar 2016 10:54:25 -0500
> From: Henrik Schmiediche
> Subject: [Linux-PowerEdge] PE R620, DSU and USB issue
> To: [email protected]
> Message-ID:
> Content-Type: text/plain; charset="utf-8"
>
>
> We are running PowerEdge Server R620 with CentOS 7. When using DSU all 
> components, we get the error message in regards to USB not being enabled:
>
> * Inventory Failure: USB is not enabled. Please enable USB and try
> update again*
>
> Except USB are enabled in the BIOS. How do I fix this?
>
> The issues appears to be in the OS Collector.
>
> [*]9 OS Collector
> Current Version : 0 Upgrade to : OSC_1.1
>
> Everything else updated(d) just fine.
>
> Regards,
> - Henrik
>
> ]# dsu --non-interactive
> Verifying catalog installation ...
> Installing catalog from repository ...
> Verifying inventory collector installation ...
> Getting System Inventory...
> Determining Applicable Updates...
> Installing Diagnostics_Application_5W2KP_LN64_OSC_1.1_X10-00...
> Collecting inventory...
> ......
> Inventory Failure: USB is not enabled. Please enable USB and try 
> update again
>
> -------------- next part --------------
> An HTML attachment was scrubbed...
> URL: 
> http://lists.us.dell.com/pipermail/linux-poweredge/attachments/20160315/3af527ac/attachment-0001.html 
>
>
> ------------------------------
>
> _______________________________________________
> Linux-PowerEdge mailing list
> [email protected]
> https://lists.us.dell.com/mailman/listinfo/linux-poweredge
>
> End of Linux-PowerEdge Digest, Vol 142, Issue 11
> ************************************************
>

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.