Re: OHCI_BE_FRAME_NO_SHIFT question

"Dale Farnsworth" <[email protected]>
Newsgroups gmane.linux.usb.devel
Message-ID <[email protected]>
On Mon, Oct 08, 2007 at 05:22:19PM +0400, Valentine Barshak wrote:
> I've just never worked with those big endian platforms which
> do not need this shift.

Then you've never worked with the Freescale mpc5200.

> IIRC, according to OHCI specs, frame number is a 16-bit value and is 
> padded with 2 zero bytes, as opposed to 32-bit value. Since it's a 
> 16-bit value, all be platforms should still have it in the first 2 bytes 
> (need the OHCI_BE_FRAME_NO_SHIFT).

Unless the implementors of said platforms mis-interpret or
mis-implement the spec.

-Dale

-------------------------------------------------------------------------