Re: smartd fails to monitor disks connected to an ASUS PIKE 2008 card
Christian Franke <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <[email protected]> |
Peter van Hoof wrote: > Hi Christian, > >>> >>> # smartctl -a /dev/disk/by-id/scsi-SATA_ST31000528AS_6VP0PCXC >>> ... >> Please provide the smartd.conf file. > > Here it is... The three commented-out lines are the disks that are > connected to the PIKE card. If I uncomment one of those, smartd > immediately exits with error 16. > > ... > #/dev/disk/by-id/scsi-SATA_ST31000528AS_6VP0PCXC -I 190 -I 194 -d ata > -a -o on -S on -s (S/../.././14|L/../(06|20)/./18) -m root > #/dev/disk/by-id/scsi-SATA_ST1000DM005_HD10S246JX0D300179 -I 194 -d > ata -a -o on -S on -s (S/../.././15|L/../(12|26)/./18) -m root > #/dev/disk/by-id/scsi-SATA_SanDisk_SDSSDX24130863401886 -I 194 -I 195 > -d ata -a -o on -S on -s (S/../.././02|L/../(03|17)/./08) -m root Try without '-d ata'. Option '-d sat' normally is the correct setting for SATA drives on Linux. Smartctl auto-detects it because you didn't specify a -d option. Thanks, Christian ------------------------------------------------------------------------------ Rapidly troubleshoot problems before they affect your business. Most IT organizations don't have a clear picture of how application performance affects their revenue. With AppDynamics, you get 100% visibility into your Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro! http://pubads.g.doubleclick.net/gampad/clk?id=84349351&iu=/4140/ostg.clktrk