smartctl database

Vlad Anisimov <[email protected]>
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <CAEnaYsaXQWctJZsQf7kfEJ58bNLFE=tRfkyO899=EVfKivk86Q@mail.gmail.com>
hi!
bought a hard disk WD RED WD40EFRX, which was established in NAS (nas4free
9).
when I viewing S.M.A.R.T. see "Not in smartctl database".
So,
in att. #1 - output S.M.A.R.T.
in att. #2 - output "smartctl -q noserial -x /dev/sdX"
in att. #3 - output "smartctl -t short /dev/sdX"

Add my HDD to database, please!

-- 
Best regards,
   Anisimov Vlad

------------------------------------------------------------------------------
Learn Graph Databases - Download FREE O'Reilly Book
"Graph Databases" is the definitive new guide to graph databases and their
applications. Written by three acclaimed leaders in the field,
this first edition is now available. Download your free book today!
http://p.sf.net/sfu/13534_NeoTech

_______________________________________________
Smartmontools-support mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-support
SMART.txt (text/plain, 4.4 KB)
=== START OF INFORMATION SECTION ===
Device Model:     WDC WD40EFRX-68WT0N0
Serial Number:    WD-WCC4E0280552
LU WWN Device Id: 5 0014ee 2091d1cc0
Firmware Version: 80.00A80
User Capacity:    4,000,787,030,016 bytes [4.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Fri Mar 14 09:46:31 2014 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever
					been run.
Total time to complete Offline
data collection: 		(53760) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 537) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x703d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0027   171   170   021    Pre-fail  Always       -       8441
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       102
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       -       1793
 10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       102
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       16
193 Load_Cycle_Count        0x0032   198   198   000    Old_age   Always       -       6369
194 Temperature_Celsius     0x0022   118   115   000    Old_age   Always       -       34
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl t short.txt (text/plain, 313 B)
$ smartctl -t short /dev/sdX
smartctl 6.2 2013-07-26 r3841 [FreeBSD 9.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

/dev/sdX: Unable to detect device type
Please specify device type with the -d option.

Use smartctl -h to get a usage summary
smartctl x.txt (text/plain, 321 B)
$ smartctl -q noserial -x /dev/sdX
smartctl 6.2 2013-07-26 r3841 [FreeBSD 9.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

/dev/sdX: Unable to detect device type
Please specify device type with the -d option.

Use smartctl -h to get a usage summary
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.