Respected Sir
We have on nexenta CE which have around 14 SSD Drives (Corsair Neutron GTX 480 GB ) drives attached to a supermicro system with 64 GB RAM
14 disk is configured as RAID10 in nexenta of total 3TB and this 3TB Lun is assingn to a Redhat Virtulization (Virtual Machine) as direct lun/passthrough to the virtual machine and the virtual machine is having 96GB Ram assigned to it and running ORACLE database
Now about 6 month the nexenta storage performs well after this much period over storage performance get degraded/deteriorating
Now our problem is the SSD Drives what we have connected to nexenta storage does not have smartmon database to check the SSD_Life_Left attribute
so we have run the smart command on some drives to identified that is their any problem with the drives so we get the following below output
smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: Corsair Neutron GTX SSD
Serial Number: 12517924000021010190
Firmware Version: M206
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue May 20 16:32:10 2014 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002e 166 166 006 Old_age Always - 0
5 Reallocated_Sector_Ct 0x0032 100 100 036 Old_age Always - 1
9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 10869
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 36
171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 4
172 Unknown_Attribute 0x0032 253 253 000 Old_age Always - 0
181 Program_Fail_Cnt_Total 0x0032 100 100 000 Old_age Always - 4
182 Erase_Fail_Count_Total 0x0032 253 253 000 Old_age Always - 0
194 Temperature_Celsius 0x0002 028 000 000 Old_age Always - 28 (Min/Max 22/34)
201 Soft_Read_Error_Rate 0x0032 100 100 000 Old_age Always - 0
204 Soft_ECC_Correction 0x0032 100 100 000 Old_age Always - 0
231 Temperature_Celsius 0x0032 092 092 000 Old_age Always - 9
234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 76126
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 95735
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 31158
250 Read_Error_Retry_Rate 0x0032 100 100 000 Old_age Always - 1202
SMART Error Log Version: 1
ATA Error Count: 15 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 15 occurred at disk power-on lifetime: 10869 hours (452 days + 21 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 ff 00 4f c2 e0 Error: IDNF
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 01 06 4f c2 00 00 31d+07:42:11.824 SMART READ LOG
b0 d5 01 01 4f c2 00 00 31d+07:42:11.824 SMART READ LOG
b0 da 00 00 4f c2 00 00 31d+07:42:11.824 SMART RETURN STATUS
b0 d1 01 01 4f c2 00 00 31d+07:42:11.824 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 00 00 31d+07:42:11.814 SMART READ DATA
Error 14 occurred at disk power-on lifetime: 10868 hours (452 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 ff 00 4f c2 e0 Error: IDNF
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 01 06 4f c2 00 00 31d+07:27:29.834 SMART READ LOG
b0 d5 01 01 4f c2 00 00 31d+07:27:29.824 SMART READ LOG
b0 da 00 00 4f c2 00 00 31d+07:27:29.824 SMART RETURN STATUS
b0 d1 01 01 4f c2 00 00 31d+07:27:29.824 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 00 00 31d+07:27:29.824 SMART READ DATA
Error 13 occurred at disk power-on lifetime: 10868 hours (452 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 ff 00 4f c2 e0 Error: IDNF
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 01 06 4f c2 00 00 31d+07:26:46.114 SMART READ LOG
b0 d5 01 01 4f c2 00 00 31d+07:26:46.114 SMART READ LOG
b0 da 00 00 4f c2 00 00 31d+07:26:46.114 SMART RETURN STATUS
b0 d1 01 01 4f c2 00 00 31d+07:26:46.114 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 00 00 31d+07:26:46.114 SMART READ DATA
Error 12 occurred at disk power-on lifetime: 10868 hours (452 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 ff 00 4f c2 e0 Error: IDNF
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 01 06 4f c2 00 00 31d+07:25:17.604 SMART READ LOG
b0 d5 01 01 4f c2 00 00 31d+07:25:17.604 SMART READ LOG
b0 da 00 00 4f c2 00 00 31d+07:25:17.604 SMART RETURN STATUS
b0 d1 01 01 4f c2 00 00 31d+07:25:17.604 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 00 00 31d+07:25:17.594 SMART READ DATA
Error 11 occurred at disk power-on lifetime: 10868 hours (452 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 ff 00 4f c2 e0 Error: IDNF
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 01 06 4f c2 00 00 31d+07:23:07.424 SMART READ LOG
b0 d5 01 01 4f c2 00 00 31d+07:23:07.424 SMART READ LOG
b0 da 00 00 4f c2 00 00 31d+07:23:07.414 SMART RETURN STATUS
b0 d1 01 01 4f c2 00 00 31d+07:23:07.414 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 00 00 31d+07:23:07.404 SMART READ DATA
SMART Self-test log structure revision number 0
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging
###########################################
Now the following below attribute
250 Read_Error_Retry_Rate 0x0032 100 100 000 Old_age Always - 1202
show that is has 1202 error while reading
so i need to know whether is their any problem with the ssd drives
Please give any suggestion by seeing the above output
Regards,
---
Disclaimer: Privileged & confidential information is contained in this message (including all attachments). If you are not an intended recipient of this message, please destroy this message immediately and kindly notify the sender by reply e-mail. Any unauthorized use or dissemination of this message in any manner whatsoever, in whole or in part, is strictly prohibited. This e-mail, including all attachments hereto, is for discussion purposes only and shall not be deemed or construed otherwise unless expressly stated. Any views or opinions presented in this email are solely those of the author and do not necessarily represent that of NJ India Invest Pvt. This communication, including any attachments,may not be free of viruses, interceptions or interference, and may not be compatible with y
our systems. You should carry out your own virus checks before opening any attachment to this e-mail. The sender of this e-mail and NJ India Invest Pvt. Ltd. shall not be liable for any dama
ge that you may sustain as a result of viruses, incompleteness of this message, a delay in receipt of this message or computer problems experienced. This message has been scanned for viruses and dangerous content by NJGroup Email Server, and is believed to be clean.
------------------------------------------------------------------------------
"Accelerate Dev Cycles with Automated Cross-Browser Testing - For FREE
Instantly run your Selenium tests across 300+ browser/OS combos.
Get unparalleled scalability from the best Selenium testing platform available
Simple to use. Nothing to install. Get started now for free."
http://p.sf.net/sfu/SauceLabs