Re: Mediasonic 8 Bay External Hard Drive Enclosure connected via USB 3.0

Graham Fleming <[email protected]>
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <[email protected]>
So, now that my smartd.conf file is working again (I didn't ever re-write it for the -d sat command), I'm seeing some errors come up when I restart smartd.

Here's an example of one of the drives in the 8-bay array (all drives report same error):
smartd[12997]: Device: /dev/sdi [SAT], ST1000NM0011, S/N:Z1N0APEA, WWN:5-000c50-03ec3daa1, FW:PA07, 1.00 TB
smartd[12997]: Device: /dev/sdi [SAT], found in smartd database: Seagate Constellation ES (SATA 6Gb/s)
smartd[12997]: Device: /dev/sdi [SAT], not capable of SMART Health Status check
smartd[12997]: Device: /dev/sdi [SAT], is SMART capable. Adding to "monitor" list.
smartd[12997]: Device: /dev/sdj [SAT], opened

Not sure exactly what SMART Health Status check is, but when I run smartctl -a on that drive, everything seems pretty good:

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.15.5-1-ARCH] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

Jul 16 09:35:27 Mediacentre sudo[13352]: pam_unix(sudo:session): session opened for user root by (uid=0)
=== START OF INFORMATION SECTION ===
Model Family:     Seagate Constellation ES (SATA 6Gb/s)
Device Model:     ST1000NM0011
Serial Number:    Z1N0APEA
LU WWN Device Id: 5 000c50 03ec3daa1
Add. Product Id:  DELL(tm)
Firmware Version: PA07
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Wed Jul 16 09:35:27 2014 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  609) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
SCT capabilities:              (0x10bd) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   080   063   044    Pre-fail  Always       -       112875577
  3 Spin_Up_Time            0x0003   095   093   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       20
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   076   060   030    Pre-fail  Always       -       42348384
  9 Power_On_Hours          0x0032   081   081   000    Old_age   Always       -       16909
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       18
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   060   049   045    Old_age   Always       -       40 (Min/Max 37/49)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       13
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       21
194 Temperature_Celsius     0x0022   040   051   000    Old_age   Always       -       40 (0 18 0 0 0)
195 Hardware_ECC_Recovered  0x001a   116   099   000    Old_age   Always       -       112875577
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       161048388714742
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       349799315
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       1194316266

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     15625         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

On Jul 15, 2014, at 10:34 PM, Christian Franke <[email protected]> wrote:

> Graham Fleming wrote:
>>   idVendor           0x152d JMicron Technology Corp. / JMicron USA Technology Corp.
>>   idProduct          0x0539 JMS539 SuperSpeed SATA II 3.0G Bridge
>>   bcdDevice           28.12
> 
> Added to drivedb.h in r3950, r3951. Please run /usr/sbin/update-smart-drivedb. Should work without "-d sat" then.
> 
> Thanks,
> Christian
> 


------------------------------------------------------------------------------
Want fast and easy access to all the code in your enterprise? Index and
search up to 200,000 lines of code with a free copy of Black Duck
Code Sight - the same software that powers the world's largest code
search on Ohloh, the Black Duck Open Hub! Try it now.
http://p.sf.net/sfu/bds
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.