Re: smart Airflow_Temperature_Cel attribute value on Micron RealSSD
Christian Franke <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <[email protected]> |
Janardhan Molumuri wrote: > I should have clarified it, i meant smartctl -H ( --health) doesn't > have an easy way to ignore some attributes. e.g. in this case 190. > There is not option specific for this rare use case (broken controller firmware, bogus drive temperature attribute). Normally -H does not check the attributes but simply prints boolean SMART RETURN STATUS info from the drive. Try "-v 190,raw48:v" option as a workaround. It prints the VALUE field as RAW and should suppress threshold check for attribute 190. If this works, you could add a local drive database entry to /etc/smart_drivedb.h, see -B option on smartctl man page. Thanks Christian ------------------------------------------------------------------------------ Want fast and easy access to all the code in your enterprise? Index and search up to 200,000 lines of code with a free copy of Black Duck Code Sight - the same software that powers the world's largest code search on Ohloh, the Black Duck Open Hub! Try it now. http://p.sf.net/sfu/bds