Re: 2TB Seagate gets msg "SMART Status command failed"
George R Goffe <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <[email protected]> |
Christian, Thank you for responding to my question. The docking station is made by SIIG, it's exact title is "SuperSpeed USB to SATA 3Gb/s Dual Docking". I should contact their tech support people for this and relate your information to them? I did the following commands to both drives, same docking station: /usr/sbin/smartctl -a -d sat /dev/sdb and /usr/sbin/smartctl -a -d sat /dev/sdc. I'm including both files below. Notice that the front part of each report is the same? Same serial number? Regards and again THANK you for responding, George... ________________________________ From: Christian Franke <[email protected]> To: George R Goffe <[email protected]> Cc: "[email protected]" <[email protected]> Sent: Saturday, August 16, 2014 1:01 PM Subject: Re: [smartmontools-support] 2TB Seagate gets msg "SMART Status command failed" George R Goffe wrote: > Hi, > > I just installed a brand new Seagate 2TB hdd, > > Model Family: Seagate Barracuda 7200.14 (AF) > Device Model: ST2000DM001-1CH164 > > > When I execute this command (/usr/sbin/smartctl -a -d sat /dev/sdc), I get the following: > > === START OF READ SMART DATA SECTION === > SMART Status command failed > Please get assistance from http://smartmontools.sourceforge.net/ > Register values returned from SMART Status command are: > ERR=0x00, SC=0x00, LL=0xb7, LM=0x2d, LH=0x04, DEV=0x40, STS=0x50 The SMART RETURN STATUS command returned LBA_MID/HIGH register values which do not make any sense. Correct values would be: LM=0x4f, LH=0xc2 -> SMART PASSED LM=0xf4, LH=0x22 -> SMART FAILED This is usually a problem of the ATA pass-through functions from the driver/firmware of the controller (which?) between smartctl and the drive. If possible, connect the drive to another controller or machine and repeat the test. > SMART overall-health self-assessment test result: PASSED > Warning: This result is based on an Attribute check. This means the smartctl did a SMART VALUE > THRESHOLD check instead and found no problems. Regards, Christian ------------------------------------------------------------------------------ _______________________________________________ Smartmontools-support mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/smartmontools-support
smart.sdb
(application/octet-stream, 5.1 KB) - not displayed
smart.sdc
(application/vnd.stardivision.calc, 5.3 KB) - not displayed