Re: smartd.conf not working

John Theodore <[email protected]>
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <CAD53fRDPW_E6FQXjxzmO40=1x3vA2UBOEGssvouxw4RQMe81EA@mail.gmail.com>
The devices do appear from the smartctl command.
On Sep 19, 2014 12:43 PM, "Christian Franke" <[email protected]>
wrote:

> John Theodore wrote:
>
>> This command below works and scans 1 disk:
>>   sudo smartctl -l ssd -d megaraid,1 -t short /dev/sdb
>>
>> I want to setup my /etc/smartd.conf so it runs a short test every night,
>> and a long test once a week. The one line in my /etc/smartd.conf is below:
>>
>> DEVICESCAN -S on -o on -a -I 194 -s (S/../.././02|L/../../6/03)
>>
>>
> If the device does not appear in "smartctl --scan-open" output, you need
> to add an extra smartd.conf entry:
>
> /dev/sdb -d megaraid,1 ...(remaining directives)...
>
> MegaRAID device scanning is implemented in the Linux version of
> smartmontools >= 6.1.
>
> Thanks,
> Christian
>
>

------------------------------------------------------------------------------
Slashdot TV.  Video for Nerds.  Stuff that Matters.
http://pubads.g.doubleclick.net/gampad/clk?id=160591471&iu=/4140/ostg.clktrk

_______________________________________________
Smartmontools-support mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-support