problem with ST3000DM001-1E6166
"Malyaev, Alexey" <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <[email protected]> |
Hi
I have USB disk ST3000DM001-1E6166 and I trying to use smartctl.exe (on Windows 8)
1st of all "smartctl.exe --scan" do not list this disk.
I have found the disk ID just by trying and I found it, but there are errors while I'm trying to get SMART information:
>smartctl.exe -a /dev/sdd -d sat
smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-win8.1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1E6166
Serial Number: W1F3DJG8
LU WWN Device Id: 5 000c50 06a26774d
Firmware Version: SC47
User Capacity: 3 000 592 982 016 bytes [3,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Nov 23 13:37:26 2014 RTZST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 600) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 370) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3081) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 109 099 006 Pre-fail Always - 24112528
3 Spin_Up_Time 0x0003 092 091 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1052
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 053 052 030 Pre-fail Always - 240531478261
9 Power_On_Hours 0x0032 091 091 000 Old_age Always - 8211
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 22
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 0 0
189 High_Fly_Writes 0x003a 099 099 000 Old_age Always - 1
190 Airflow_Temperature_Cel 0x0022 058 042 045 Old_age Always In_the_past 42 (Min/Max 21/50 #89)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
193 Load_Cycle_Count 0x0032 074 074 000 Old_age Always - 53923
194 Temperature_Celsius 0x0022 042 058 000 Old_age Always - 42 (0 20 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 3811h+41m+54.701s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 15366105288
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 42397751117
Read SMART Log Directory failed: IOCTL_SCSI_PASS_THROUGH_DIRECT failed, Error=1117
Read SMART Error Log failed: IOCTL_SCSI_PASS_THROUGH_DIRECT failed, Error=1117
Read SMART Self-test Log failed: IOCTL_SCSI_PASS_THROUGH_DIRECT failed, Error=1117
Read SMART Selective Self-test Log failed: IOCTL_SCSI_PASS_THROUGH_DIRECT failed, Error=1117
Also while the errors are displayed my computer is hanging for several minutes.
Is it possible to solve the problem?
Thanks in advance,
_________________________________
Alexey Malyaev | Program Manager, BU UC, MERA | N.Novgorod, Russia | +7 (831) 2788858
------------------------------------------------------------------------------
Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server
from Actuate! Instantly Supercharge Your Business Reports and Dashboards
with Interactivity, Sharing, Native Excel Exports, App Integration & more
Get technology previously reserved for billion-dollar corporations, FREE
http://pubads.g.doubleclick.net/gampad/clk?id=157005751&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-support mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-support