Re: SNMP reporting wrong max bandwidth
"Dave Shield" <[email protected]>
| Newsgroups | gmane.network.net-snmp.user |
|---|---|
| Message-ID | <[email protected]> |
On 28/11/2007, Tim Donnelly <[email protected]> wrote: > Manually walking the remote servers from Isis using the command: snmpwalk > -v1 -c public grdb ifSpeed snmpwalk -v2c -c public grdb ifhighspeed gives > the following output: > > IF-MIB::ifSpeed.1 = Gauge32: 10000000 > IF-MIB::ifSpeed.2 = Gauge32: 100000000 > IF-MIB::ifSpeed.3 = Gauge32: 0 > IF-MIB::ifSpeed.4 = Gauge32: 0 That's the output of walking the ifSpeed column. What is the output of walking 'ifHighSpeed' ? (Note the capitalisation). Try running the agent using '-DmibII/interfaces' That should display some debugging information relating to the IF-MIB processing. What does this report when you walk the ifSpeed column. Dave ------------------------------------------------------------------------- SF.Net email is sponsored by: The Future of Linux Business White Paper from Novell. From the desktop to the data center, Linux is going mainstream. Let it simplify your IT future. http://altfarm.mediaplex.com/ad/ck/8857-50307-18918-4 _______________________________________________ Net-snmp-users mailing list [email protected] Please see the following page to unsubscribe or change other options: https://lists.sourceforge.net/lists/listinfo/net-snmp-users