Re: generated attributes and syncrepl
Howard Chu <[email protected]> Thu, 28 May 2026 14:25:31 +0100
| Newsgroups | gmane.network.openldap.devel |
|---|---|
| Message-ID | <[email protected]> |
Emmanuel Dreyfus wrote: > On Wed, May 27, 2026 at 04:09:33PM +0000, Emmanuel Dreyfus wrote: >> I was happy about it, but the discovered that syncrepl consumer still >> misses the second modification, even if the master still has a more >> recent entryCSN than the replica. There must be a mising bit somewhere. > > Following-up on myself... > > I can force the sync by making another modification to the entry, > or by restarting the replica. > > The replica's syncrepl consumer is configured as refreshAndPersist. > Once the initial synchronisation is done, I understand the master > is supposed to push the changes to the replica. It seems it fails > to do so with my internal modification. > Either your internal modification is somehow bypassing the overlay stack, or you have a flag set on the op that makes syncprov ignore it. -- -- Howard Chu CTO, Symas Corp. http://www.symas.com Director, Highland Sun http://highlandsun.com/hyc/ Chief Architect, OpenLDAP http://www.openldap.org/project/