Re: [rancid] end of run not found
heasley <[email protected]>
| Newsgroups | gmane.network.rancid |
|---|---|
| Message-ID | <[email protected]> |
Thu, Dec 13, 2018 at 07:55:29AM +0000, Wayne Eisenberg: > Regarding some PowerConnect N2000/3000/4000 series switches, I am getting "End of run not found" errors. If I use the smc type that is recommended in the rancid.types.base file, I have the added pleasure of getting "missed cmd(s): show version, dir, show vlan". Trying cisco as a type doesn't change the 'end of run' error, although I don't miss any commands. Trying my powerconnect type that I made earlier also results in 'end of run not found'. > > Running 'clogin -c"dir,show version,show running-config" switchname' works perfectly and returns to the command prompt. > > How do I troubleshoot 'end of run not found'? > it means that it did not find the end of the config. look at the raw output and srancid -dl <hostname> for missed command matches. I suspect that it srancid is not recognizing the prompt due to mangled input or unexpected characters in the prompt. _______________________________________________ Rancid-discuss mailing list [email protected] http://www.shrubbery.net/mailman/listinfo/rancid-discuss