Re: [rancid] end of run not found

heasley <[email protected]>
Newsgroups gmane.network.rancid
Message-ID <[email protected]>
Thu, Dec 13, 2018 at 07:55:29AM +0000, Wayne Eisenberg:
> Regarding some PowerConnect N2000/3000/4000 series switches, I am getting "End of run not found" errors. If I use the smc type that is recommended in the rancid.types.base file, I have the added pleasure of getting "missed cmd(s): show version, dir, show vlan". Trying cisco as a type doesn't change the 'end of run' error, although I don't miss any commands. Trying my powerconnect type that I made earlier also results in 'end of run not found'.
> 
> Running 'clogin -c"dir,show version,show running-config" switchname' works perfectly and returns to the command prompt.
> 
> How do I troubleshoot 'end of run not found'?
> 

it means that it did not find the end of the config.  look at the raw
output and srancid -dl <hostname> for missed command matches.  I suspect
that it srancid is not recognizing the prompt due to mangled input or
unexpected characters in the prompt.